SC-2060 Board
Chapter 2
SC-206X Series User Manual
2-4
© National Instruments Corporation
Power Requirement (from Host Board or External Power Supply)
Power consumption (at +5 VDC)
Typical
71 mA
±
5% with all inputs low
111 mA
±
5% with all inputs high
Maximum
210 mA
Note:
The power specifications pertain to the power supply of the host computer when using
internal power or to the external supply connected at screw terminal J2 when using external
power.
Physical
Board dimensions (including standoffs)
5.2 by 4.9 by 1.8 in.
I/O connectors
18 screw terminals
One 26-pin male ribbon-cable connector
Operating Environment
Temperature
0
°
to 70
°
C
Relative humidity
5% to 90% noncondensing
Storage Environment
Temperature
-55
°
to 125
°
C
Relative humidity
5% to 90% noncondensing
Mounting and Connection to Data Acquisition Boards
The SC-2060 has metal standoffs so the board can sit on a workbench near the host computer. You
can use an optional rack-mount chassis, which can be fitted with a flat acrylic plastic cover. The SC-
2060 grounds to its metal standoffs, and thus to the rack, when it is mounted in the chassis.
Warning:
The SC-2060 must be completely enclosed if any onboard voltages or voltage differences
across the optoisolators can exceed 30 V.
The SC-2060 connects to the data acquisition boards listed in Table 2-1 via the appropriate
SC-205X Series cable adapter board.