Table 3.

 MAX Configuration Options

NI Controller

NI SCXI-1127/1128/1129/ 1160/1161/1163R/

1190/1191/1192 Switches

All Other NI SCXI

Switches

 

 

 

NI 407x, NI 4065,
M Series, NI 4021

NI-DAQmx/Traditional NI-DAQ (Legacy)

NI-DAQmx

NI 4060

Traditional NI-DAQ (Legacy)

-

NI USB

NI-DAQmx

Note

 

The NI 4060 device can only control

NI SCXI-1127/1128/1129/1160/1161/1163R/1190 switch modules configured using
Traditional NI-DAQ (Legacy). For software support information, refer to the
preceding table.

1. Launch MAX by navigating to 

Start

»

All Programs

»

National Instruments

»

NI MAX

 or

by clicking the NI MAX desktop icon.

2. Right-click 

Devices and Interfaces

. Select 

Create New

.

3. In the 

Create New

 window, go to 

NI-DAQmx SCXI Chassis

. Select the SCXI chassis

you want to add. Configure the following settings:

Select the switch controller (

NI USB-1359

 or 

NI 407x

) cabled to the communicating

SCXI switch module from the 

Chassis Communicator

 drop-down listbox. If MAX

detects only one communicating device, this device is selected as the chassis

communicator by default and the listbox is dimmed.

(

NI SCXI kits only

) Select the module slot connected to the chassis communicator

from the 

Communicating SCXI Module Slot

 drop-down list.

In the 

Chassis Address

 text box, enter the appropriate chassis address setting. The

correct chassis address jumper settings are shown in the interactive DIP switch

graphic in the configuration window. Make sure the software setting matches the

actual chassis address setting on the SCXI chassis.

If you want NI-DAQ to automatically detect the SCXI modules in the chassis, check

Auto-Detect All Modules

.

4. Click 

Save

 when you are finished.

5. Right-click the SCXI chassis you just added. Select 

Configure

.

6. In the 

SCXI Chassis Configuration

 window, click the 

Modules

 tab. Select the module

you want to add from the 

Modules

 drop-down listbox.

7. Click 

Details

 to configure the module settings.

Connecting Signals to Switch Terminal Blocks

Refer to the documentation for your terminal block to install the terminal block and connect

signals to the NI switch product.

16 | 

NI Switches Getting Started Guide

 | ni.com

Summary of Contents for SCXI-1130

Page 1: ...SCXI 1130...

Page 2: ...t described in this document Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product Contents Electromagnetic Compa...

Page 3: ...oid your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Caution To ensure the...

Page 4: ...device into the chassis Installing the Software You must install the NI SWITCH driver software before installing the NI switch product NI switch modules are packaged with NI SWITCH and NI DAQmx Each...

Page 5: ...tall Refer to the following table Table 1 NI Switch Controllers and Supported NI SCXI Switches SCXI Rear Connector 10 or 50 pin NI Switch Module NI Switch Controllers NI 4021 or NI PXI PCI 4065 or NI...

Page 6: ...1128 1129 1160 1161 1163R 1190 switch modules configured using Traditional NI DAQ Legacy 2 Identify the adapter kit s required to cable the switch controller or the computer to the NI SCXI switch mod...

Page 7: ...1161 1163R 1190 switch modules configured using Traditional NI DAQ Legacy Related Information Refer to the NI Switches Help for more information about NI switch controllers and adapter kits Installat...

Page 8: ...SCXI slot 5 Screw the switch front panel to the chassis front panel mounting rail Installation Procedure 2 Install an NI SCXI switch module in any of the following configurations NI SCXI 1000 1001 ch...

Page 9: ...to the OFF position If you are using multiple SCXI chassis ensure each chassis has a unique binary address Note Earlier chassis use jumpers inside the chassis front panel instead of chassis address sw...

Page 10: ...witch controller to the switch module Notice that an NI E Series or M Series device can directly cable only to an NI SCXI switch module with a 50 pin rear connector Figure 3 Cabling an NI E Series or...

Page 11: ...ar Connector Switch Module 1 7 6 or 4 5 3 2 1 NI SCXI Switch Module with a 10 Pin Rear Connector 2 HVAB Connector 3 10 Pin Rear Connector 4 SH9MD AUX Cable 5 NI Switch Controller 6 NI SCXI 1359 Cable...

Page 12: ...module with a 50 pin rear connector for the NI 4021 407x or NI PXI PCI 4065 Figure 5 Cabling an NI 4021 407X or an NI PXI PCI 4065 to a 50 Pin Rear Connector Switch Module 1 2 4 5 3 1 NI SCXI Switch M...

Page 13: ...ssis 3 Controller 1 Power off and unplug the chassis 2 Install the switch controller including any adapter kit s as described in the switch controller documentation 3 NI PXI 1010 only Set the chassis...

Page 14: ...r adapter directly to an NI SCXI switch module with a 10 pin rear connector Refer to the following figure and complete the following steps to install an NI SCXI switch module and cable it to an NI USB...

Page 15: ...odule connects to the black lower right 10 pin rear connector of the NI USB 1359 9 Screw the backplane adapter to the chassis mounting rail 10 Power on the chassis You must power on the chassis before...

Page 16: ...4 Touch any metal part of the chassis to discharge static electricity 5 Insert the switch module into the SCXI slot 6 Screw the switch front panel to the chassis front panel mounting rail 7 Connect on...

Page 17: ...e communicating device this device is selected as the chassis communicator by default and the listbox is dimmed NI SCXI kits only Select the module slot connected to the chassis communicator from the...

Page 18: ...functions C or LabWindows CVI Available at Program Files IVI Foundation IVI Drivers niSWITCH Installed examples for Visual C C are in the NI SWITCH Readme Refer to the Creating an Application with Mic...

Page 19: ...ocate examples with the NI Example Finder Within LabVIEW or LabWindows CVI select Help Find Examples and navigate to Hardware Input and Output Modular Instruments ANSI C or Microsoft Visual C C Locate...

Page 20: ...ation development environment ADE appropriate for your application Getting Started with LabVIEW Getting Started with LabWindows CVI 2 3 NI Switches ni com switches Services ni com services Updates ni...

Page 21: ...ity does not alter module specifications PXI communication Hybrid slot compatibility supports existing PXI timing and PXI triggering capabilities Refer to your NI PXI PXI Express chassis documentation...

Page 22: ...ion If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac E...

Page 23: ...atents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party...

Reviews: