National Instruments Corporation
1-1
SCXI-1141/1142/1143 User Manual
1
Introduction
This chapter describes the SCXI-1141/1142/1143 module, and lists the
contents of the SCXI-1141/1142/1143 kit.
About the SCXI-1141/1142/1143 Module
The SCXI-1141/1142/1143 module has eight lowpass filters and eight
differential-input amplifiers. The SCXI-1141 has elliptic filters; the
SCXI-1142, Bessel filters; and the SCXI-1143, Butterworth filters.
You can use the SCXI-1141/1142/1143 module for lowpass filtering and
antialiasing applications as well as for general-purpose signal amplification
and filtering. The SCXI-1141/1142/1143 module works with National
Instruments E Series MIO DAQ devices and with the SCXI-1200 data
acquisition and control module. You can use one DAQ device to control
several SCXI-1141/1142/1143 modules, in combination with other SCXI
modules in a chassis. Each SCXI-1141/1142/1143 module can multiplex its
channels into a single channel of the DAQ device, although separate
outputs are also available. You can multiplex the output of several
SCXI-1141/1142/1143 modules into a single channel, thus greatly
increasing the number of analog input signals that the DAQ device can
digitize.
The SCXI-1304 shielded terminal block has screw terminals for easily
connecting signals to the SCXI-1141/1142/1143 module and is the terminal
block recommended for use with this module.
Refer to Appendix A,
, for detailed SCXI-1141/1142/1143
module specifications.