Chapter 2
Installing and Configuring the SCXI-1141/1142/1143 Module
SCXI-1141/1142/1143 User Manual
2-10
ni.com
Configuring and Testing the SCXI-1141/1142/1143
Module
Use MAX to configure and test the SCXI-1141/1142/1143 module. If you
need help during the configuration process, open the MAX Help file by
selecting from the menu
Help»Help Topics»NI-DAQ
. Follow these steps
to configure the SCXI system:
1.
Double-click the
Measurement & Automation Explorer
icon on
the desktop.
If you are adding new modules to an existing chassis, go to step 4. If you
are inserting modules into an empty chassis, go to step 2.
2.
Add a new chassis by right-clicking
Devices and Interfaces
and
selecting
Insert
from the pop-up menu. Select the appropriate chassis
from the list box and click
OK
.
3.
Configure the chassis by selecting a
Chassis ID
. This is an integer
value you choose to uniquely identify the chassis for programming and
scanning.
a.
Select the
Chassis Address
. This is needed to address the chassis
in a multichassis SCXI system.
•
Unless you are using multiple chassis with the same DAQ
device, select a chassis address of zero, which is the factory
default setting for all SCXI chassis.
•
If you are using multiple chassis, refer to the SCXI chassis
user manual for further information.
•
For remote SCXI chassis, you also need to select the
Baud
Rate
and
COM Port
.
b.
After completing the chassis configuration, click
Next
.
4.
You now have the choice of automatically detecting which modules are
installed in the chassis or manually adding them:
•
If you have just added the chassis to
Devices and Interfaces
and
are using an E Series MIO DAQ device, you can automatically
detect the modules.
•
If the chassis is already listed in
Devices and Interfaces
, you
must add new modules manually.
Go to the appropriate section that follows to continue the software
configuration of the chassis.