background image

Summary of Contents for SCXI-1324

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Page 2: ...use the SCXI 1324 high voltage terminal block with the SCXI 1160 module The SCXI 1324 high voltage terminal block has 48 screw terminals for easy signal connection to the 16 relays inside the SCXI 11...

Page 3: ...res are connected to the device hazardous voltages may exist even when the equipment is turned off To avoid a shock hazard do not perform procedures involving cover or shield removal unless you are qu...

Page 4: ...njuries resulting from incorrect signal connections If high voltages 30 Vrms and 42 4 Vpeak or 60 VDC are present you must connect a safety earth ground wire to the terminal block safety ground solder...

Page 5: ...in lb 7 Connect safety earth ground to the safety ground solder lug Refer to the Safety Information section for connection information 8 Reinstall the strain relief bar and tighten the strain relief s...

Page 6: ...r refer to Figure 3 while performing the following steps 1 Connect the module front connector to its mating connector on the terminal block 2 Tighten the top and bottom thumbscrews on the back of the...

Page 7: ...returning to service Specifications Electrical Common mode isolation Channel to channel 250 Vrms Channel to ground 250 Vrms Load or signal current 2A maximum per channel Environment Operating tempera...

Page 8: ...hone support in the United States dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 03 9879 5166 Austria 0662 45 79 90 0 Belgium 02 757 00 20...

Page 9: ......

Page 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: