SCXI-1324 Installation Guide

Do not substitute parts or modify equipment. Because of the danger of introducing 
additional hazards, do not install unauthorized parts or modify the device. Return the 
device to National Instruments for service and repair to ensure that its safety features are 
not compromised.

When using the device with high common-mode voltages, you must insulate your signal 
wires for the highest input voltage. National Instruments is not liable for any damages or 
injuries resulting from inadequate signal wire insulation. Use only 26-14 AWG wire with 
a rating of 300 V and 60 °C for signals that may come in contact with 250 V.

When connecting or disconnecting signal lines to or from the SCXI terminal block screw 
terminals, make sure the lines are powered off. Potential differences between the lines and 
the SCXI ground create a shock hazard while you connect the lines.

Connections, including power signals to ground and vice versa, that exceed any of the 
maximum signal ratings on the SCXI device can create a shock or fire hazard or can 
damage any or all devices connected to the SCXI chassis, the host computer, and the SCXI 
device. National Instruments is not liable for any damages or injuries resulting from 
incorrect signal connections.

If high voltages (

30 V

rms

 and 42.4 V

peak

 or ±60 VDC) are present, you must connect a 

safety earth ground wire to the terminal block safety ground solder lug, shown in Figure 1. 
This complies with safety agency requirements and protects against electric shock when 
the terminal block is not connected to the chassis. To connect the safety earth ground to the 
safety ground solder lug, run an earth ground wire in the cable from the signal source to 
the terminal block. National Instruments is not liable for any damages or injuries resulting 
from inadequate safety earth ground connections.

Do not loosen or re-orient the safety ground solder lug hardware when connecting the 
safety ground wire; to do so reduces the safety isolation between the high voltage and 
safety ground.

Connecting Signal Wires to the Terminal Block

Note

Refer to the 

Safety Information

 section before removing equipment covers or 

connecting or disconnecting any signal wires.

When connecting your signals to the SCXI-1324, follow the labeling on the 
SCXI-1324 as indicated in Figure 2.

To connect the signal to the terminal block, perform the following steps, 
referring to Figures 1 and 2 as necessary:

1.

Unscrew the top cover screws and remove the cover.

2.

Loosen the strain-relief screws and remove the strain-relief bar.

3.

Run the signal wires through the strain-relief opening. You can add 
insulation or padding if necessary.

Summary of Contents for SCXI-1324

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Page 2: ...use the SCXI 1324 high voltage terminal block with the SCXI 1160 module The SCXI 1324 high voltage terminal block has 48 screw terminals for easy signal connection to the 16 relays inside the SCXI 11...

Page 3: ...res are connected to the device hazardous voltages may exist even when the equipment is turned off To avoid a shock hazard do not perform procedures involving cover or shield removal unless you are qu...

Page 4: ...njuries resulting from incorrect signal connections If high voltages 30 Vrms and 42 4 Vpeak or 60 VDC are present you must connect a safety earth ground wire to the terminal block safety ground solder...

Page 5: ...in lb 7 Connect safety earth ground to the safety ground solder lug Refer to the Safety Information section for connection information 8 Reinstall the strain relief bar and tighten the strain relief s...

Page 6: ...r refer to Figure 3 while performing the following steps 1 Connect the module front connector to its mating connector on the terminal block 2 Tighten the top and bottom thumbscrews on the back of the...

Page 7: ...returning to service Specifications Electrical Common mode isolation Channel to channel 250 Vrms Channel to ground 250 Vrms Load or signal current 2A maximum per channel Environment Operating tempera...

Page 8: ...hone support in the United States dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 03 9879 5166 Austria 0662 45 79 90 0 Belgium 02 757 00 20...

Page 9: ......

Page 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: