background image

National Instruments

, NI

,

 

ni.com

, and SCXI

 are trademarks of National Instruments Corporation. Product and company names mentioned herein 

are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your CD, or 

ni.com/patents

.

371199A-01 

©

 1995, 2002 National Instruments Corp. All rights reserved. January 2002

INSTALLATION GUIDE

SCXI -1353 S

HIELDED

 C

ABLE

 A

SSEMBLY

This guide describes how to install the National Instruments SCXI-1353 
shielded cable assembly between a 100-pin E Series data acquisition 
(DAQ) device and two SCXI modules. The SCXI-1353 consists of an 
SH1006868 cable, an SCXI-1349 shielded cable adapter, and an 
AI-48/DIO-24 adapter.

Introduction 

The SCXI-1353 makes a low-noise, long-distance connection between 
a 100-pin E Series DAQ device and two SCXI modules. The SH1006868 
cable is available in lengths of 1, 2, 5, and 10 m. The SH1006868 cable 
is Y-shaped, with a 100-pin male connector and two 68-pin female 
connectors. One branch of the cable is labeled 

MIO-16

, and the other 

branch is labeled 

EXTENDED I/O

.

The 100-pin connector of the cable attaches to a 100-pin E Series DAQ 
device. The 68-pin connector on the MIO-16 branch of the cable attaches 
to an SCXI-1349. The 68-pin connector on the EXTENDED I/O branch of 
the cable attaches to an AI-48/DIO-24. The SCXI-1349 and AI-48/DIO-24 
can attach to a variety of SCXI modules. Both these adapters have breakout 
connectors that you can use to connect to other SCXI accessories, such as 
the SCXI-1180 and the SCXI-1351.

What You Need to Get Started

To install and use the SCXI-1353, you need the following items:

SCXI-1353 shielded cable assembly (included in this kit)

SH1006868 cable

SCXI-1349 shielded cable adapter

AI-48/DIO-24 adapter

SCXI chassis

Summary of Contents for SCXI-1353

Page 1: ...e long distance connection between a 100 pin E Series DAQ device and two SCXI modules The SH1006868 cable is available in lengths of 1 2 5 and 10 m The SH1006868 cable is Y shaped with a 100 pin male...

Page 2: ...on in the software such as menu items and dialog box options Bold text also denotes parameter names This icon denotes a note which alerts you to important information italic Italic text denotes varia...

Page 3: ...istivity The following is a description of pollution degrees Pollution degree 1 means no pollution or only dry nonconductive pollution occurs The pollution has no influence Pollution degree 2 means th...

Page 4: ...derived circuits Installing the SCXI 1353 Shielded Cable Assembly Perform the following steps to install the SCXI 1353 Refer to Figure 1 for the installation procedure Figure 1 SCXI 1353 Installation...

Page 5: ...nect the end of the cable labeled EXTENDED I O to the 68 pin connector of the AI 48 DIO 24 9 Connect the 100 pin end of the cable to the I O connector of the DAQ device 10 Use the tie wraps to secure...

Page 6: ...23 AISENSE 19 19 62 DAC0OUT 20 20 22 DAC1OUT 21 21 21 EXTREF 22 22 20 AOGND 23 23 54 55 DGND 24 33 24 33 4 7 9 12 13 15 18 35 36 39 44 50 53 DIO0 25 25 52 DIO4 26 26 19 DIO1 27 27 17 DIO5 28 28 51 DIO...

Page 7: ...9 GPCTR0_GATE 48 48 3 GPCTR0_OUT 49 49 2 FREQ_OUT 50 50 1 Pins 1 through 9 and pins 35 through 43 on the 68 pin connector are not connected Table 2 Extended I O Cable Connections Signal Names Connecto...

Page 8: ...0 ACH33 PB6 69 19 59 ACH41 GND 70 20 25 ACH34 PB5 71 21 24 ACH42 GND 72 22 58 ACH35 PB4 73 23 23 ACH43 GND 74 24 57 AISENSE2 PB3 75 25 56 AIGND GND 76 26 22 ACH36 PB2 77 27 55 ACH44 GND 78 28 21 ACH37...

Page 9: ...0 SCXI 1141 SCXI 1160 SCXI 1161 SCXI 1162 SCXI 1162HV SCXI 1163 SCXI 1163R SCXI 1180 or SCXI 1181 ACH47 GND 84 34 18 ACH48 PA6 85 35 17 ACH56 GND 86 36 51 ACH49 PA5 87 37 16 ACH57 GND 88 38 50 ACH50 P...

Page 10: ...161 SCXI 1162 SCXI 1162HV SCXI 1163 SCXI 1163R SCXI 1180 or SCXI 1181 You can connect the EXTENDED I O cable using the AI 48 DIO 24 to the following SCXI modules SCXI 1162 SCXI 1162HV SCXI 1163 SCXI 1...

Page 11: ...b sites provide up to date contact information support phone numbers e mail addresses and current events If you have searched the technical support resources on our Web site and still cannot find the...

Page 12: ...320982B 01 Jan02 320982B 01 South Africa 11 805 8197 Spain 91 640 0085 Sweden 08 587 895 00 Switzerland 056 200 51 51 Taiwan 02 2528 7227 United Kingdom 01635 523545...