SCXI-1356 Shielded Cable Installation Guide

Environmental

Operating temperature............................ 0 to 50 °C

Storage temperature ............................... –20 to 70 °C 

Humidity ................................................ 10 to 90% RH, noncondensing

Maximum altitude .................................. 2000 meters

Pollution degree (indoor use only)......... 2

Safety

The SCXI-1356 meets the requirements of the following standards 
for safety and electrical equipment for measurement, control, and 
laboratory use:

EN 61010-1:1993/A2:1995, IEC 61010-1:1990/A2:1995

UL 3111-1:1994

CAN/CSA c22.2 no. 1010.1:1992/A2:1997

Technical Support Resources

National Instruments Web Support

NI Web support is your first stop for help in solving installation, 
configuration, and application problems and questions. Online 
problem-solving and diagnostic resources include frequently asked 
questions, knowledge bases, product-specific troubleshooting wizards, 
manuals, drivers, software updates, and more. Web support is available 
through the Technical Support section of 

ni.com

.

Worldwide Support

NI has offices located around the world to help address your support needs. 
You can access our branch office Web sites from the Worldwide Offices 
section of 

ni.com

. Branch office Web sites provide up-to-date contact 

information, support phone numbers, e-mail addresses, and current events. 

If you have searched the technical support resources on our Web site 
and still cannot find the answers you need, contact your local office or NI 
corporate. For telephone support in the United States, dial 512 795 8248. 
For telephone support outside the United States, contact your local branch 
office: 

Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, 
Brazil 011 3262 3599, Canada (Calgary) 403 274 9391, 

Summary of Contents for SCXI-1356

Page 1: ...00 pin male connector at one end and two 68 pin female connectors on the branched end One 68 pin connector branch is labeled MIO 16 and the other is labeled ACH16 ACH63 Refer to Figure 1 for the parts...

Page 2: ...n introduction to a key concept This font also denotes text that is a placeholder for a word or value that you must supply monospace Text in this font denotes text or characters that you should enter...

Page 3: ...a temporary conductivity caused by condensation must be expected Pollution degree 3 means that conductive pollution occurs or dry nonconductive pollution occurs that becomes conductive due to condensa...

Page 4: ...circuits and circuit breakers Other examples of installation category III are wiring including cables bus bars junction boxes switches socket outlets in the building fixed installation and equipment f...

Page 5: ...CXI chassis 5 Connect the MIO 16 branch of the cable to the 68 pin connector of the SCXI 1349 6 Plug the socket connector of the AI 48 DIO 24 into the rear signal connector of the SCXI module or the f...

Page 6: ...SCXI Modules 2 SCXI Chassis 3 SCXI 1349 Adapter 4 MIO 16 Branch of SCXI 1356 Shielded Cable 5 VXI MIO Series Module 6 96 Pin Male Connector End of SCXI 1356 Shielded Cable 7 ACH16 ACH63 Branch of SCX...

Page 7: ...MIO Series module you use determines which SCXI modules you can use with the SCXI 1356 Connecting the SCXI 1356 to a VXI MIO Series Module The MIO 16 branch of the cable brings the MIO 16 portion of t...

Page 8: ...63 or SCXI 1163HV SCXI 1180 or SCXI 1181 Table 1 lists the pin assignments for connections between the VXI MIO Series module and the MIO 16 branch of the cable Table 1 Cable Connections for the MIO 16...

Page 9: ...O1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 DIO3 C26 47 31 DIO7 A27 48 32 5V A28 8 14 34 35 SCANCLK C27 46 36 DIO4 A25 19 26 DIO1 B25 17 27 DIO5 C25 51 28 DIO2 A26 49 29 DIO6 B26 16 30 D...

Page 10: ...h panel or the SCXI 1181 breadboard module Table 2 lists the pin designations for connections between the VXI MIO Series module and the ACH16 ACH63 cable GPCTR1_OUT B30 40 43 PFI5 UPDATE C30 6 44 PFI6...

Page 11: ...B12 27 15 ACH31 A12 61 16 ACH32 C11 26 17 ACH40 B11 60 18 ACH33 A11 59 19 ACH41 C10 25 20 ACH34 B10 24 21 ACH42 A10 58 22 ACH35 C9 23 23 ACH43 B9 57 24 AISENSE2 A9 56 25 AIGND B17 22 26 ACH36 C8 55 2...

Page 12: ...mode voltage Channel to earth 250 V installation category II Channel to channel 250 V installation category II ACH48 A6 17 35 ACH56 C5 51 36 ACH49 B5 16 37 ACH57 A5 50 38 ACH50 C4 49 39 ACH58 B4 15 40...

Page 13: ...sources include frequently asked questions knowledge bases product specific troubleshooting wizards manuals drivers software updates and more Web support is available through the Technical Support sec...

Page 14: ...ermany 089 741 31 30 Greece 30 1 42 96 427 Hong Kong 2645 3186 India 91 80 535 5406 Israel 03 6393737 Italy 02 413091 Japan 03 5472 2970 Korea 02 3451 3400 Malaysia 603 9596711 Mexico 001 800 010 0793...

Reviews: