DIN160 Cable Installation Instructions
24
ni.com
Specifications
Maximum voltage ..................................................150 V, CAT I
Caution
The NI PXI-2510 module and the DIN160 cable accessory can operate at various ambient
temperatures and currents as shown in the following specifications.
Caution
Do
not
connect to MAINs supply circuits (e.g., wall outlets) of 115 or 230 VAC. Refer to
the
Read Me First: Safety and Electromagnetic Compatibility
document for more information about
Measurement Categories.
Weight ....................................................................848.6 g (29.9 oz)
Environment
Operating temperature ...........................................0 °C to 55 °C
Storage temperature ...............................................–20 °C to 70 °C
Relative humidity...................................................5% to 85%, noncondensing
Pollution Degree ....................................................2
Maximum altitude..................................................2,000 m
Indoor use only.
Table 11.
NI PXI-2510 and DIN160 Operating Currents
Current
NI PXI-2510
Module Alone
NI PXI-2510 Module
with DIN160 Cable
Operating temperature range
0–55 °C
0–55 °C
0–40 °C
Maximum total module current
64 A
32 A
48 A
Maximum current per channel
2 A
1 A
1.5 A
*
*
The DIN160 cable accessory is constructed with six sets of cable bundles. The above currents are valid for any channel
combination. Table 12 describes how to balance signal loading to achieve the maximum 2 A/channel across the six cable bundles.
Table 12.
Maximum Currents of NI PXI-2510 with DIN160 Cable When Operating at 2A/channel
Channel Range
Maximum Total Current
Across Channel Range (0 °C to 40 °C)
ch0 to ch11
14 A
ch12 to ch19
14 A
ch20 to ch31
14 A
ch32 to ch43
14 A
ch44 to ch55
14 A
ch56 to ch67
14 A