National Instruments Corporation
3
NI UMI-7774/72 User Guide and Specifications
eight digital outputs on the controller. Also, the UMI-7774/72 features a host bus monitor power
interlock that automatically disables the drive if the host computer is shut down or the motion
input/output interface cable is disconnected.
Figure 1 shows the UMI-7774.
Figure 1.
UMI-7774/72 Connector, LED, and Switch Locations
The UMI-7774/72 includes the following features:
•
D-SUB connectivity, which provides easy and durable connectivity to third-party devices.
•
5 to 30 V limits and home switch/sensor compatibility.
•
Global Stop inputs for global shutdown of all axes.
•
Optical isolation on inhibit signals, Global Stop inputs, triggers, limits, home, and digital I/O. This
feature enables 24 VDC signaling capability. Also, the isolation can help break ground loops in the
system and reduce the effects of noise and voltage transients.
•
Global and per-axis status LEDs.
•
Access to eight digital inputs and eight digital outputs.
•
Panel, DIN rail, or rack mountable.
1
Power Connection LEDs
2
Power Connector
3
Global Stop D-SUB
4
Analog Input D-SUB
5
Per-Axis Polarity Switches
6
Per-Axis LED Status Indicators
7
Per-Axis Control Connector
8
Per-Axis Feedback Connector
9
Trigger/Breakpoint Connector
10 Digital I/O Connector
11 UMI to 73xx Controller Digital
I/O Connector
12 UMI to 73xx Controller Motion
I/O Connector
FAULT
FWD
HOME
REV
FAULT
FWD
HOME
REV
FAULT
FWD
HOME
REV
FAULT
FWD
HOME
REV
LIMIT LED
FAULT
ENABLE
LIMIT LED
FAULT
ENABLE
LIMIT LED
FAULT
ENABLE
LIMIT LED
FAULT
ENABLE
12
11
2
10
9
8
7
5
1
6
3
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com