Verifying the Kit Contents

2

3

5

4

6

1

NI USRP-2920R

NI USRP-2920R

1. USRP Device
2. AC/DC Power Supply and Power Cable
3. Shielded Ethernet Cable

4. SMA (m)-to-SMA (m) Cable
5. 30 dB SMA Attenuator
6. Getting Started Guide (This Document) and

Safety, Environmental, and Regulatory
Information Document

Notice

 

If you directly connect or cable a signal generator to your device, or if you

connect multiple USRP devices together, you must connect a 30 dB attenuator to the
RF input (RX1 or RX2) of each receiving USRP device.

Other Required Item(s)

In addition to the kit contents, you must provide a computer with available gigabit Ethernet
interface.

Optional Items

LabVIEW Modulation Toolkit (MT), available for download at 

ni.com/downloads

 and

included in LabVIEW Communications System Design Suite, which includes MT VIs
and functions, examples, and documentation

Note

 

You must install the LabVIEW Modulation Toolkit for proper operation

of the NI-USRP Modulation Toolkit example VIs.

LabVIEW Digital Filter Design Toolkit, available for download at 

ni.com/downloads

 and

included in LabVIEW Communications System Design Suite

LabVIEW MathScript RT Module, available for download at 

ni.com/downloads

USRP MIMO sync and data cable, available at

 ni.com

, to synchronize clock sources

USRP-2930/2932 Getting Started Guide

  | 

© National Instruments

  | 

3

Summary of Contents for USRP-2930

Page 1: ...Guidelines 4 Environmental Characteristics 4 Installing the Software 4 Installing the Software Using NI Package Manager 4 Installing the Software Using the Driver Download Page 5 Installing the Device...

Page 2: ...arge ESD from damaging the device ground yourself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer c...

Page 3: ...nts you must provide a computer with available gigabit Ethernet interface Optional Items LabVIEW Modulation Toolkit MT available for download at ni com downloads and included in LabVIEW Communications...

Page 4: ...Software You must be an Administrator to install NI software on your computer 1 Install an application development environment ADE such as LabVIEW or LabVIEW Communications System Design Suite 2 Follo...

Page 5: ...pts to complete the installation 4 When the installer completes select Shut Down in the dialog box that prompts you to restart shut down or restart later Installing the Device Install all the software...

Page 6: ...utputs MIMO Expansion Configuring the Device Setting Up the Network Ethernet Only The device communicates with a host computer over gigabit Ethernet Set up the network to enable communication with the...

Page 7: ...address of the device and you must configure the network 1 Verify that your device is powered on and connected to your computer using the gigabit Ethernet interface 2 Select Start All Programs Nation...

Page 8: ...ted then click the Refresh Devices List button to scan for USRP devices Configuring Multiple Devices with Ethernet You can connect multiple devices in the following ways Multiple Ethernet interfaces O...

Page 9: ...llows a single gigabit Ethernet adapter on the computer to interface with multiple USRP devices connected to the switch Assign the host Ethernet interface a subnet and assign each device an address in...

Page 10: ...ther software defined radio SDR functionality Note You can access additional examples from the Code Sharing Community at ni com usrp From the Start menu at Start All Programs National Instruments NI U...

Page 11: ...st to confirm that the device transmits and receives signals and is connected correctly to the host computer 1 Attach the included 30 dB attenuator to one end of the SMA m to SMA m cable 2 Connect the...

Page 12: ...e to update the devices Updating Device Firmware and FPGA Images Optional The firmware and FPGA images for USRP devices are stored in the device internal memory You can reload the FPGA image or firmwa...

Page 13: ...et correctly 11 Close the utility Related Information Refer to the Load the Images onto the On board Flash USRP N Series Only section of the UHD USRP2 and N Series Application Notes Why Doesn t the US...

Page 14: ...192 168 10 2 in the command prompt where 192 168 10 2 is the IP address for your USRP device 4 Press Enter If the uhd_find_devices command does not return the listing for your device the firewall may...

Page 15: ...Changing the IP Address on page 7 Why Does the Device Not Connect to the Host Interface The host Ethernet interface must be a gigabit Ethernet interface to connect to the USRP device Ensure the connec...

Page 16: ...F IN This terminal is not used for this device PPS IN Input terminal for the PPS timing reference PPS IN is an SMA f connector with an impedance of 50 and is a single ended input channel PPS IN accept...

Page 17: ...ff The firmware is not loaded Green The firmware is loaded E Indicates the reference lock status of the LO on the device Off There is no reference signal or the LO is not locked to a reference signal...

Page 18: ...S IN Input terminal for the PPS timing reference PPS IN is an SMA f connector with an impedance of 50 and is a single ended input channel PPS IN accepts 0 V to 3 3 V TTL and 0 V to 5 V TTL signals MIM...

Page 19: ...ff The firmware is not loaded Green The firmware is loaded E Indicates the reference lock status of the LO on the device Off There is no reference signal or the LO is not locked to a reference signal...

Page 20: ...plete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Applicat...

Page 21: ...EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and h...

Reviews: