Appendix A Specifications
VXI-1500 User Manual
A-6
© National Instruments Corporation
Backplane
Table A-6.
Backplane Specifications
Characteristic
Description
Size
C-sized, 13 slot,
VXIbus Specification, Revision 1.4
Bus Grant/Interrupt
Acknowledge
Auto-configuring (jumperless)
VXIbus CLK10 and
CLK100 Distribution
Differential tracking and line length
equalization utilized to minimize signal
skew. On-board socketed ECL buffers
utilized for distribution.
Backplane Bare-Board
Material
UL 94 V-0 recognized
(File No. E 116551)
96-Pin Backplane
Connectors
Conform to IEC 603-2 and are
UL 94 V-0 rated
Mechanical
Table A-7.
Mechanical Specifications
Characteristic
Description
Overall Dimensions
Standard Mainframe (7U)
Height
Width
Depth
39.2 cm (15.45 in.)
43.7 cm (17.20 in.)
71.3 cm (28.02 in.)
Note: 1.27 cm (.5 in.) added to
height when feet are installed.
Weight
28.18 kg (62 lb.) with no modules
installed