NI WSN-3212 User Guide and Specifications
12
ni.com
Using the Integrated Panel Mount Slots
You can also mount the NI WSN-3212 to a panel using the integrated panel mount slots as shown in
Figure 10.
1.
Attach three number 8 or M4 pan head screws in the mounting panel leaving 0.1 in. space under
the head of each screw. Refer to Figure 3 for the correct hole pattern and dimensions.
2.
Slide the NI WSN-3212 device onto the panel.
Note
In this configuration, the NI WSN-3212 is held in place only by the weight of the device and
the friction of the screw attachment. Use the DIN rail clip or panel mount accessories in high
vibration environments.
Figure 10.
Integrated Panel Mount Slots
Caution
Disconnect power before removing the device from the panel.
Setting Up the NI WSN-3212 Device
The following sections discuss setting up the NI WSN-3212 for use.
Installing the Software
You must be an Administrator to install NI software and devices on your computer. Before connecting
the hardware, install the following software in the following order:
1.
NI LabVIEW, available at
ni.com/support
.
2.
NI-WSN and NI MAX, which are included on the software installation disc included with your
NI WSN gateway and are also available for download at
ni.com/support
.
Note
After installation of NI-WSN, the
NI Wireless Sensor Network Getting Started Guide
is
available from
Start»All Programs»National Instruments»NI-WSN
.