Removing the Low Flow Side
A typical installation would be equipped with drain and piping valves To inspect or replace components of the Low Flow side,
close the upstream and downstream valves However, if the installation does not have a drain valve, proceed as follows to
relieve pressure See
UPSTREAM AND DOWNSTREAM VALVES MUST BE CLOSED BEFORE ATTEMPTING TO REMOVE METER HEAD FROM
HOUSING. FAILURE TO DO SO CAN LEAD TO THE HEAD BEING "EJECTED" FROM HOUSING, CAUSING PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
1 Loosen each of the Low Flow Cover Assembly bolts about 1-1/2 turns Do not completely remove the bolts
2 If the O-ring between the Low Flow Cover Assembly and the housing is secure and not leaking, pry the Measuring
Element Assembly loose by inserting a screwdriver blade where the head and housing join together
BE SURE THAT ANY WATER COMING OUT OF THE METER HEAD DOES NOT SPRAY ONTO ELECTRICAL EQUIPMENT AND
CREATE A SHOCK HAZARD.
3 Allow the meter to drain and relieve internal pressure
4 When pressure is relieved, remove the head bolts
Low Flow
Register
High Flow
Register
Cover Seal
Bypass Seal
Turbo Head
Assembly
Bottom Plate
Chamber
Assembly
Figure 13: Removing the low flow side
Servicing Parts and Assemblies
June 2016
RCS-UM-00076-EN-04
Page 18