TROUBLESHOOTING
100 Avon Street, P.O. Box 1547
Charlottesville, VA 22902
Tel: 434-295-9126 Tech Support: 800-247-9796 Fax: 888-239-0778
Revision: 11/98 Page -
41
-
NATIONAL
INCORPORATED
A.
Blocked Flow Restrictor.
Locate the
RF354
restrictor, located in
airline #8 of the Cutter Motor Carriage Flow Cylinder, and follow the
procedures on
Page 49
for removal and cleaning.
B.
Solenoid Valve Malfunction.
Refer to
Page 45
for Solenoid
identification and troubleshooting.
CUTTER MOTOR FLOW TO THE RIGHT IS TOO SLOW OR WILL NOT
FLOW AT ALL:
Blocked Flow Restrictor.
Locate the
IFC-32
restrictor/check valve, located
in airline #7 of the Cutter Motor Carriage Flow Cylinder, and follow the
procedures on
Page 49
for removal and cleaning.
CUTTER MOTOR FLOW TO THE RIGHT IS TOO FAST:
A.
Air Leak.
Check the fittings and air connections on the flow cylinder and the
solenoid for leaks.
B.
Open Check Valve.
Locate the
IFC-32 restrictor
/check valve, located in
airline #7 of the Lens Drive Carriage Flow Cylinder, and follow the
procedures on
Page 49
for removal and cleaning.
DIFFERENTIAL WILL NOT OPEN:
A.
Blocked Flow Restrictor.
Locate the
IFC-11/IFC-15
restrictor/check valve
assembly, located in airline #9, and follow the procedures on
Page 49
for
removal and cleaning.
B.
Solenoid Valve Malfunction.
Refer to
Page 45
for Solenoid identification
and troubleshooting.
DIFFERENTIAL WILL NOT CLOSE:
Blocked Flow Restrictor.
Locate the
IFC-11/IFC-15
restrictor/check valve
assembly, located in airline #9, and follow the procedures on
Page 49
for
removal and cleaning.
DIFFERENTIAL CLOSES TOO FAST:
A.
Air Leak.
Check the fittings and air connections on the differential cylinder
and the solenoid for leaks.
B.
Open Check Valve.
Locate the
IFC-11/IFC-15
restrictor/check valve
assembly, located in airline #9, and follow the procedures on
Page 49
for
removal and cleaning.