INSTALLATION PROCEDURES
100 Avon Street, P.O. Box 1547
Charlottesville, VA 22902
Tel: 434-295-9126 Tech Support: 800-247-9796 Fax: 888-239-0778
Revision Date: 11/98 Page -
8
-
2.
Feed the vacuum power cord through the bench opening and lay it towards the rear of the bench, as it will
be plugged into the edger.
3.
Turn the power switch on the vacuum to the ON position, as its cycling will be automatically controlled.
4.
Insert the end of the 2 ½” flex vacuum hose into the coupler on the bottom of the edger from below the
bench. This connects the hose to the chip chute, the device in the edger that captures the plastic debris.
5.
Maintaining a gentle curve between the chip chute and the vacuum, connect the other end of the 2 ½” hose
to the vacuum inlet.
NOTE:
The vacuum inlet is the
lower
hole in the vacuum canister. The 2 ½” hose
can be cut to the shortest length possible with a utility knife and a pair of wire cutters. The shorter the
hose, the more effective the suction.
ATTACHING THE COMPRESSED AIR LINE:
1.
The compressed air connection is on the right side of the edger towards the rear. Install the filter regulator
assembly provided with the edger by inserting it into the quick-connect bulkhead fitting.
2.
Attach the quick disconnect onto the end of the air line to be used. The ring on the quick disconnect fitting
can be pulled back, and the air line pushed onto the male fitting of the filter regulator assembly.
3.
Verify the pressure is at 80 psi on the filter regulator gauge. If not, locate the adjustment knob on top of the
filter regulator assembly. Move the yellow locking ring to the up position, adjust the pressure, then push
the yellow locking ring down into the locked position. It is required that 80 psi be maintained for the edger
to operate properly. Clockwise will increase pressure, counter-clockwise will decrease pressure.
4.
The pattern tracking pressure gauge on the front panel of the edger is factory set and should read 35 psi
when the inlet pressure reads 80 psi. If it does not read 35 psi, adjust it accordingly, using the adjustment
knob on the control panel directly below the gauge.
ELECTRICAL CONNECTIONS:
1.
Plug the vacuum cord that was laid on the rear of the bench into the appropriate socket on the back of the
edger.
2.
Check to assure that all panel switches are in the
raised
, rather than the depressed, position. Also, ensure
that the power switch on the right side of the control panel is in the OFF position.
3.
The HORIZON II Edger is designed to be connected to a grounded 115V, 60 Hz power supply. The wall
receptacle should be of
at
least 15 amp capacity.
The power consumption of the edger is 12.4 Amps.
Connect the supplied power cord from the back of the edger to a 155VAC wall receptacle
.
OPERATING CONDITIONS:
The HORIZON II is designed for indoor use only. The edger is designed to operate safely at a temperature
range of 5° C to 40° C, at altitudes up to 2000 meters.
THE EDGER IS NOW SET UP TO OPERATE.