Optional Configurations
25
SLWU055A – May 2008 – Revised May 2016
Copyright © 2008–2016, Texas Instruments Incorporated
TSW3070EVM: Amplifier Interface to Current Sink DAC - Arbitrary Waveform
Generator Demonstration
9
Optional Configurations
9.1
External VCXO
It is possible to configure the TSW3070EVM to use an external VCXO for application flexibility. J13 and
J14 can be used in position 2-3 to select an external VCXO or clock signal.
9.2
Transformer Passive Output
The board is by default set up to output signals through the OPA695, THS3091, and THS3095. These
devices can be individually bypassed to a transformer output, if needed. To bypass the OPA695, move R6
to R109, and R15 to R134. To bypass the THS3091 and THS3095, move R20 to R135, and R27 to R136.
Figure 17. DAC5682Z Resistor Jumper Configuration
The blue denotes the default configuration (operational amplifier output), whereas the yellow denotes the
transformer output option.
Table 6. Optional Output Signal Path
R109
R134
R15
R6
Bypass OPA695
Install
Install
Remove
Remove
Use OPA695 (default)
Remove
Remove
Install
Install
R135
R136
R20
R27
Bypass THS3091 and THS3095
Install
Install
Remove
Remove
Use THS3095 (default)
Remove
Remove
Install
Install