background image

#800-160 

Replacement bulb, 12v 20 watt halogen bi-pin 

#965-160 

Eyepiece reticle, 10mm/100 div. 

 

LIMITED LIFETIME WARRANTY 

 

National warrants this microscope to be free from defects in material and workmanship under normal use and service 
for the life of the instrument. The warranty does not cover damage resulting from abuse or misuse, repairs or 
alterations performed by other than authorized repair technicians, or damage occurring in transit. The warranty does 
not cover bulbs, power supplies, rechargers, batteries, fuses, cords, or add-on accessories such as mechanical 
specimen holders that are not built into the microscope stage as an integral part of original manufacture. Warranty 
does not cover lenses that have become inoperable due to excessive dirtiness as a result of misuse or lack of normal 
maintenance.  
 
Any cameras and software supplied with this microscope are warranted from date of purchase as follows:  
 

Camera, 1-year limited warranty:  

Manufacturer warrants camera to be free from defects in material and 

workmanship under normal use and service for 1 year from date of purchase.  It does not cover damage 
resulting from abuse or misuse, repairs or alterations performed by other than the manufacturer, or damage 
occurring in transit. 
 

Software, 90-day limited warranty:

  Manufacturer warrants software to be free from defects in material and 

workmanship under normal use and service for 90 days from date of purchase. 

 
Other than set forth above, National hereby disclaims all warranties, express or implied, of fitness for a particular 
purpose. 

 

While it is not necessary to register your purchase of a microscope, any camera or software must be registered by 
completing and mailing the warranty registration card enclosed with such product.  

 

For warranty service, instrument should be well packed to avoid damage in transit, accompanied by a description of 
the difficulty and return instructions, and shipped postage prepaid to National at the address below. National will repair 
or replace at no charge and return postage prepaid. 

For customers living outside the United States, National will 

provide standard warranty service.  However, all inbound & outbound costs are the responsibility of the consumer. 

 

If failure was caused by misuse, alterations, accident or abnormal conditions of operation, an estimate for repairs will 
be submitted for approval prior to work being performed. 

 

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. If you 
have questions concerning this product or warranty, contact the dealer from which it was purchased. You may also 
contact National at the following address and ask for warranty assistance. 

 

If you have questions concerning this product or warranty, contact dealer from which it was purchased.  Or contact 
National, asking for warranty assistance. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DC5-163

Page 1: ...YOUR MICROSCOPE SERIAL NUMBERS 1 Microscope serial number This number etched on back arm of microscope is the number under which your warranty is registered 2 Microscope DM number This number found on...

Page 2: ...ng specimen holder to stage Knobs controlling X and Y movement of mechanical stage Revolving nosepiece Viewing head of microscope Sliding interpupillary adjustment grips located on both left and right...

Page 3: ...instruction manuals this one and separate supplement documentation K Calibration slide L USB 2 0 PCI card with driver CD and user manual M USB cable for connecting to computer N Dustcover O Warranty c...

Page 4: ...nsert 32mm diameter blue filter OPERATION Your microscope is fully functional as a standard microscope The following instructions apply to operation of the microscope Refer to Supplement to Documentat...

Page 5: ...view is observed through both tubes and images blend into one interpupillary distance is corrected for your eyes Check the interpupillary scale and note index reading for future reference in case othe...

Page 6: ...t lens of the objective 1 Use of a very small amount of immersion oil is required 2 All air bubbles must be removed from between lens and slide by rotating nosepiece back and forth MICROSCOPE SPECIFIC...

Page 7: ...g a camel hairbrush Or use air to blow dust and lint off surfaces Use of compressed air in a can available at any computer supply store is a good source of clean air C Cleaning eyepiece lenses Do not...

Page 8: ...DC power jack Lamp burned out Replace lamp Lamp flickers Lamp loose in socket Push lamp pins into lamp socket Image does not focus Cover slip on specimen slide too thick Use 0 17mm thick cover slip S...

Page 9: ...e from defects in material and workmanship under normal use and service for 90 days from date of purchase Other than set forth above National hereby disclaims all warranties express or implied of fitn...

Page 10: ...all Motic toll free tech support at 877 901 4141 SOFTWARE INSTALLATION Software will automatically load when using Windows XP and above please follow on screen instructions Note There is no Mac softwa...

Page 11: ...USB 2 0 card included for Desktops only Windows 2000 and above DirectX 9 or above Recommended Requirements Pentium 4 or AMD 2500XP 512MB Ram 1Gig Hard Disk space 128MB AGP Video Card USB 2 0 card incl...

Page 12: ...Open the computer case Refer to your computer user manual for more details 4 Find an available PCI slot and remove the slot bracket Save the bracket screw for later use 5 Align the NEC PCI to USB 2 0...

Reviews: