Nations Technologies Inc.
Tel
:
+86-755-86309900
:
info@nationstech.com
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
203
/
631
Bit field
Name
Description
010: Update - The update event is selected as the trigger output (TRGO). For example, a
master timer clock can be used as a slave timer prescaler.
011: Compare pulse - Triggers the output to send a positive pulse (TRGO) when the
TIMx_STS.CC1ITF is to be set (even if it is already high), when a capture or a comparison
succeeds.
100: Compare - OC1REF signal is used as the trigger output (TRGO).
101: Compare - OC2REF signal is used as the trigger output (TRGO).
110: Compare - OC3REF signal is used as the trigger output (TRGO).
111: Compare - OC4REF signal is used as the trigger output (TRGO).
3
CCDSEL
Capture/compare DMA selection
0: When a CCx event occurs, a DMA request for CCx is sent.
1: When an update event occurs, a DMA request for CCx is sent.
2
CCUSEL
Capture/compare control update selection
0: If TIMx_CTRL2.CCPCTL = 1, they can only be updated by setting CCUDGN bits
1: If TIMx_CTRL2.CCPCTL = 1, they can be updated by setting CCUDGN bits or a rising
edge on TRGI.
Note: This bit only applied to channels with complementary outputs.
1
Reserved
Reserved, the reset value must be maintained
0
CCPCTL
Capture/ Compare preloaded control
0: No preloading of CCxEN, CCxNEN and OCxMD bits occurs.
1: Preloading of CCxEN, CCxNEN and OCxMD bits occurs. they are updated only when a
commutation event COM occurs (CCUDGN bit set or rising edge on TRGI depending on
CCUSEL bit)
Note: This bit only applied to channels with complementary outputs.
Slave mode control register (TIMx_SMCTRL)
Offset address: 0x08
Reset value: 0x0000
Bit field
Name
Description
15
EXTP
External trigger polarity
This bit is used to select whether the trigger operation is to use ETR or the inversion of ETR.
0: ETR active at high level or rising edge.
1: ETR active at low level or falling edge.
14
EXCEN
External clock enable
This bit is used to enable external clock mode 2, and the counter is driven by any active edge
on the ETRF signal in this mode.