Bit field
Name
Description
000: indicates the CC1 event of timer 1 100: indicates the TRGO event of timer 3
001: indicates the CC2 event of timer 1 101: indicates the CC4 event of timer 4
010: indicates the CC3 event of timer 1 110: EXTI line 0~15/TIM8_TRGO event
011: indicates the CC2 event of timer 2 111: SWSTRRCH
16
Reserved
Reserved, the reset value must be maintained
15
EXTJTRIG
External trigger conversion mode for injected channels
This bit is set and cleared by software to enable or disable external triggering events that can
start injection sequence conversion.
0: Start conversion without external events.
1: Use an external event to start the conversion.
14:12
EXTJSEL[2:0]
External event select for injected sequence
These bits select the External event used to trigger the injected sequence conversion.
The triggering configuration of ADC is as follows
000: indicates the TRGO event of timer 1 100: indicates the CC4 event of timer 3
001: indicates the CC4 event of timer 1 101: indicates the TRGO event of timer 4
010: indicates the TRGO event of timer 2 110: EXTI line 0~15/TIM8_CC4 event
011: indicates the CC1 event of timer 2 111: SWSTRJCH
11
ALIG
Data alignment
This bit is set and cleared by the software. Refer to Table 17-3 and Table 17-4.
0: Right-aligned.
1: Left-aligned.
10:9
Reserved
Reserved, the reset value must be maintained
8
ENDMA
Direct memory access mode
This bit is set and cleared by the software. See the DMA Controller chapter for details.
0: Do not use DMA mode.
1: Use DMA mode.
7:3
Reserved
Reserved, the reset value must be maintained
2
ENCAL
A/D calibration
This bit is set by software to start calibration and cleared by hardware at the end of calibration.
0: Calibration completed;
1: Starts calibration.
1
CTU
Continuous conversion
This bit is set and cleared by the software. If this bit is set, the conversion continues until the bit
is cleared.
0: Single conversion mode.
1: Continuous conversion mode.
0
ON
A/D converter ON/OFF
This bit is set and cleared by the software. When the bit is' 0 ', writing '1' will wake the ADC
from power-off mode.
When the bit is' 1 ', writing '1' starts the conversion. The application should note that there is a
delay t
STAB
between the time the converter is powered on and the time the conversion begins, see