30
/
631
Bit field
Name
Description
1: No reset occurs after entering the STOP2 mode.
Note: This bit is read-only.
2
WDG_SW
Set watchdog
0: Hardware watchdog;
1: Software watchdog.
Note: This bit is read-only.
1
RDPRT1
Read protection L1 level protection
0: Read protection L1 level is not enabled;
1: Read protection L1 level is enabled.
Note: This bit is read-only.
0
OBERR
Option byte error
When this bit is '1', it means that the option byte does not match its complement.
Note: This bit is read-only.
2.2.4.2.9
Write protection register (FLASH_WRP)
Address offset: 0x20
Reset value: 0xFFFF FFFF
Bit field
Name
Description
31:0
WRPT
Write protect
This register contains the write protection option byte loaded by option byte area.
0: Write protection takes effect;
1: Write protection is invalid.
Note: These bits are read-only.
2.2.4.2.10
ECC register
(
FLASH_ECC
)
Address offset: 0x24
Reset value: 0x0000 0000