Nations Technologies Inc.
Tel
:
+86-755-86309900
:
info@nationstech.com
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
567
/
631
Figure 25-12 Various CAN frames
\\
\\
Notes:
1. SOF = Start Of Frame
2. ID = Identifier
3. RTR = Remote Transmission Request
4. IDE = Identifier Extension Bit
5. r0,r1 = Reserved Bit
6. DLC = Data Length Code
7. 0 <= N <= 8
8. CRC = Cyclic Redundancy Code
9. ACK = Acknowledge bit
10. EOF = End of Frame
11.SRR = 0
12.Error flag: 6 dominant bits if node is error
active else 6 recessive bits.
13. send pause: applies to error passive nodes only.
Arbitration Field 12bit
Data Frame (Standard identifier) 44 + 8 * Nbit
ID[10:0]
DLC
CRC
\\
EOF
S
O
F
RT
R
ID
E
r0
A
CK
Ctrl Field 6bit
Data[N]
Data Field 8*Nbit
CRC Field 16bit
2bit
7bit
Inter-Frame Space
Inter-Frame Space
or Overload Frame
ID[28:18]
DLC
CRC
\\
\\
EOF
ID[17:0]
S
O
F
RT
R
r1
r0
A
CK
S
RR
ID
E
Arbitration Field 32bit
Ctrl Field 6bit
Data[N]
Data Field 8*Nbit
CRC Field 16bit 2bit
7bit
Data Frame (Extended Identifier) 64 + 8 * Nbit
Inter-Frame Space
Inter-Frame Space
or Overload Frame
Arbitration Field 12bit
Remote Frame 44bit
ID[10:0]
DLC
CRC
EOF
S
O
F
RT
R
ID
E
r0
A
CK
Ctrl Field 6bit
CRC Field 16bit
2bit
7bit
Inter-Frame Space
Inter-Frame Space
or Overload Frame
\\
\\
Flag Echo 6bit
Error Flag 6bit
Error Delimiter 1+7bit
Error Frame
Data Frame or
Remote Frame
Inter-Frame Space
or Overload Frame
send pause 8bit
INT 3bit
Bus Idle
Inter-Frame Space
Any Frame
Data Frame or
Remote Frame
\\
Overload
Echo 6bit
Overload Flag
6bit
Overload Delimiter
1+7bit
Overload Frame
End Of Frame or
Error Delimiter or
Overload Delimiter
Inter-Frame Space