Nations Technologies Inc.
Tel
:
+86-755-86309900
:
info@nationstech.com
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
592
/
631
Bit field
Name
Description
31:1
Reserved
Reserved, the reset value must be maintained.
0
FINITM
Filter init mode
Initialization mode settings for all filter groups.
0: The filter group works in normal mode;
1: The filter group works in initialization mode.
CAN filter mode register (CAN_FM1)
Address offset: 0x204
Reset value: 0x0000 0000
Notes
: You can only write to this register when you set CAN_FMC.FINITM bit and put the filter in initialization
mode.
Bit field
Name
Description
31:28
Reserved
Reserved, the reset value must be maintained.
13:0
FBx
Filter mode
Working mode of filter group X
0: Two 32-bit registers of CAN_FiRx work in identifier mask mode;
1: Two 32-bit registers of CAN_FiRx work in identifier list mode.
CAN filter scale register (CAN_FS1)
Address offset: 0x20C
Reset value: 0x0000 0000
Notes
: You can only write to this register when you set CAN_FMC.FINITM bit and put the filter in initialization
mode.