Reset and clock control (RCC)
Reset Control Unit
Supports the following three types of reset:
Power Reset
System Reset
Low power domain Reset
Power reset
A Power reset occurs in the following circumstances:
Power-on reset (POR reset).
Brown-out reset(BOR reset).
When exiting STANDBY mode.
When returning from STANDBY mode, resets all registers except low-power domains.
Other generated power resets will reset all registers (see
The reset source in the figure will finally act on the NRST pin and remain low during the reset process.
System reset
Except the reset flags in the Control/Status Register (RCC_CTRLSTS)and the registers in the low power domain (see
Figure 3-1), a system reset sets all registers to their reset values.
A system reset is generated when one of the following events occurs:
A low level on the NRST pin (external reset)
Window watchdog end of count condition (WWDG reset)
Independent watchdog end of count condition (IWDG reset)
Software reset (SW reset)
Low power management reset
MMU protection reset
RAM parity error reset
EMC reset
The reset source can be identified by checking the reset flags in the Control/Status Register (RCC_CTRLSTS) and
Low Power Domain Control Register(RCC_LDCTRL).