   Amber:  Warning is detected. Unit will shutdown at any time. Please check error code to  

troubleshoot the unit. 

 

   Red: 

Error is detected and unit has shutdown. Please check error code to troubleshoot  
the unit. 

  

 
Understanding the Error Code 

Code 

Condition 

Corrective Action 

E01 

Unit has sensed input under voltage 
and has shutdown 

Recharge battery immediately and 
restart unit 

E02 

Unit has sensed input over voltage 
and has shutdown 

Check battery voltage or if any external 
charger is connected to the battery bank 

E03 

Unit output has sensed overload or 
short circuit and was shutdown 

Check load connected to the output. 
Reduce load and restart the unit 

E04 

Unit has sensed internal 
temperature was high and has 
shutdown 

Turn unit off and wait for 15 minutes 
before restarting. Check if any object 
has blocked the air flow of the unit 

E05 

Unit has sensed input voltage is low 
and warning occurs 

Recharge battery as unit will shutdown 
shortly 

E06 

Unit has sensed load connected is 
close to overload shutdown limit 
(Not applicable for 38210, 38215) 

Reduce load 

E07 

Unit has sensed internal 
temperature is high and is close to 
thermal shutdown limit 

Reduce load and check if any ventilation 
of the unit is blocked 

 

AC Load on Power Inverter 

Although the Power Inverter can provide high surge power up to two times the rated output power, 
some appliances may still trigger on the inverter protection system. A higher power inverter is 
required for those appliances. 
For 38210, 38215 modified sinewave inverter, some appliances like speed controllers found in 
some fans, power tools and some power tools

’ AC charger may not like the modified sine wave 

generate by the inverter, those appliances may not work or may be damaged if they are 
connected to the inverter. If you are unsure about powering any device with the inverter, contact 
the manufacturer of the device. 

 
 
Estimate Run time on Load 

Following run time is an estimate based on using a 12V-120AH battery bank for reference. Actual 
run time may vary. 
 

Load 

Consumption 

Estimate Run time 

Cordless Phone 

5W 

180 hrs 

Clock/Radio 

8W 

135 hrs 

Table Lamp 

40W/60W 

27 hrs/ 18 hrs 

Freezer (8.8 cu. ft.) 

80W 

15 hrs 

20” LCD TV 

100W 

11.5 hrs 

Refrigerator (18 cu. ft.) 

120W 

9 hrs 

Sump Pump (1/2 hp) 

350W 

3 hrs 

Microwave (mid-size) 

1000W 

49 min 

Coffee Maker 

1200W 

37 min 

 

Summary of Contents for 38210

Page 1: ... every precaution has been taken to ensure the accuracy of the contents of this guide Nature Power Technology assumes no responsibility for errors or omissions Nature Power reserves the right to make changes to the product specifications and this manual without notice Therefore check the website for manual updates as necessary www naturepowerproducts com Important Please be sure to read and save t...

Page 2: ...Page 2 Table of Contents 1 INTRODUCTION 3 2 PRODUCT DESCRIPTION 4 3 INSTALLATION 5 4 UNIT OPERATION 8 5 TROUBLESHOOTING 10 6 SPECIFICATIONS 10 7 WARRANTY 11 ...

Page 3: ...eries have someone nearby in case of an emergency Study and follow all the battery manufacturer s specific precautions when installing using and servicing the battery connected to the inverter Wear eye protection and gloves Avoid touching your eyes while using this unit Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soa...

Page 4: ... is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help LIMITATIONS ON USE Do not use in...

Page 5: ...n placing the unit allow a minimum of three inches of space around the unit for optimal ventilation Understanding the unit features AC Output Front Panel Picture shown 38210 DC Input Rear Panel Picture shown 38210 Material Prepare for Installation Typical Wiring block diagram of the Power Inverter Important Choose your AWG by the distance you will mount your inverter from the battery We recommend ...

Page 6: ...onnect the DC power between the power inverter and the battery bank during service maintenance or trouble shooting DC Input and Grounding Cable Use of low resistance wire is required for all the DC connections between the inverter and the battery bank For 38210 38310 uses minimum 2 AWG wire with maximum cable length of 5 feet For 38215 use minimum 1 0 AWG wire with maximum cable length of 5 feet I...

Page 7: ... or serious injury Connect the grounding cable s ring terminal to the unit ground screw Connect the other side of the cable to the common grounding point Power Inverter DC Input Connection CAUTION Reverse the DC Input terminal will damage the unit and cannot be repaired Damage caused by reverse polarity connection is not covered by the warranty Connect one end of the negative DC input cable to the...

Page 8: ...tion to perform a monthly test on the GFCI to ensure the GFCI is functioning properly Turn unit on and plug a small AC load 40W light bulbs to the GFCI Check the AC load is ON Press Test button and observe a click sound Check AC load is turned off Press RESET button and check the AC load is back ON again 4 UNIT OPERATION WARNING RISK OF EQUIPMENT DAMAGE For 38210 38215 Do not plug surge protected ...

Page 9: ...15 Reduce load E07 Unit has sensed internal temperature is high and is close to thermal shutdown limit Reduce load and check if any ventilation of the unit is blocked AC Load on Power Inverter Although the Power Inverter can provide high surge power up to two times the rated output power some appliances may still trigger on the inverter protection system A higher power inverter is required for tho...

Page 10: ...TIONS Note Specifications are subject to change without notices Specification Modified Sinewave Series True Sinewave Series 38210 38215 38310 38320 Inverter AC Output Power 1000W 1500W 1000W 2000W AC Output Current 8 3A 12 5A 8 3A 16 6A AC Surge Power Peak 2000W 3000W 2000W 4000W AC Output Voltage 120 VAC 60 Hz AC Output Waveform Modified Sinewave True Sinewave Nominal DC Input Voltage 12 5 VDC No...

Page 11: ...s If you are experiencing any problems with your unit please contact our customer service department at info naturepowerproducts com or Phone 1 800 588 0590 before returning product to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store If such a unit is returned less than one year...