Understanding the LED indicators
‘Power’ indicator: Indicator turn on indicate unit is ON.
‘Fault’ indicator: Indicator turns on indicate fault was detected. Unit has shutdown. To reset unit,
remove the fault condition and reset unit by using the toggle switch and turn
unit off and on again.
Understanding the fan operation
The fan on the unit will automatically turns on when it sense the internal temperature of the unit reach
to its preset level.
AC Load on Power Inverter
Although the Power Inverter can provide high surge power up to two times the rated output power,
some appliances may still trigger on the inverter protection system. A higher power inverter is required
for those appliances.
For 38204 , with modified sine wave output, some appliances like speed controllers found in some
fans, power tools and some power tools’ AC charger may not like the modified sine wave generated
by the inverter, those appliances may not work or may be damaged if they are connected to the
inverter. If you are unsure about powering any device with the inverter, contact the manufacturer of the
device.
Estimate Run time on Load
Following run time is an estimate based on using a 12V-120AH battery bank for reference. Actual run
time may vary. those appliances may not work or may be damaged if they are.
One Year Limited Warranty
The limited warranty program is the only one that applies to this unit, and it sets forth all the
responsibilities of Nature Power. There is no other warranty, other than those described herein. Any
implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration
to the duration of this warranty.
This unit is warranted, to the original purchaser only, to be free of defects in materials and
workmanship for one year from the date of purchase without additional charge. The warranty does not
extend to subsequent purchasers or users.
Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price
of the unit under any circumstances. Incidental and consequential damages are specifically excluded
from coverage under this warranty.
This unit is not intended for commercial use. This warranty does not apply to damage to units from
misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity
power sources.
If you are experiencing any problems with your unit, please contact our customer service department
at
info@naturepowerproducts.com
or Phone
1-800-588-0590
before returning product to retail store.
After speaking to a customer service representative, if products are deemed non-working or
malfunctioning, the product may be returned to the purchasing store.
If such a unit is returned less than one year from the purchase date, manufacturer will repair the unit
or, at its discretion, replace it, free of charge. If the unit is repaired, new or reconditioned replacement
parts may be used, at manufacturer’s discretion. A unit may be replaced with a new or reconditioned
unit of the same or comparable design. The repaired or replaced unit will then be warranted under
these terms for the remainder of the warranty period. The customer is responsible for the shipping
charges on all returned items.
Limitations:
This warranty does not cover accessories, such as adapters and batteries, damage or defects result
from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage
or exposure to sunlight), accidents, damage during shipping to our service facility, alterations,
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and
maintenance, fire and flood.
Nature Power Inverters are Made in China.
Power Inverter DC Input Connection:
•
Connect one end of the negative DC input cable to the Power Inverter DC negative terminal
(black). Connect the other end of the negative DC input cable to the battery negative terminal.
• Make sure the Disconnect Switch is in the OFF position.
• Connect one end of the positive DC input cable to the Power Inverter DC positive terminal (red).
Connect the other end of the positive DC input cable to one of the terminal of the Disconnect
Switch.
• Connect a DC input cable between the other terminal of the Disconnect Switch and one side of
the terminal of thefuse holder.
• Connect a DC input cable between the other terminal of the fuse holder and the battery positive
terminal.
• Install the selected fuse to the fuse holder.
• Turn Disconnect Switch to ON position.
Connect unit using the Lighter plug cable:
CAUTION:
Due to the limitations of the 12V lighter plug socket in vehicles, the unit should be used
with the DC cable with lighter plug only to supply AC power to products that require 150W
(120VAC/1.3 A) or less. If the appliance requires more than 150W, use the optional DC cable
clips
for battery connection.
• Attach the red ring-type connector to the positive (+) DC terminal (red) on the power inverterand
connect the black ring type connector to the negative (-) DC terminal (black) on the Power inverter.
• Tighten the nut on each DC terminal.
• Insert the light plug of this cable to the fused 12V lighter plug socket.
• Unit is ready for use.
Connect unit using the Battery clips cable:
CAUTION:
Please be sure all the connections are tight before the use of the unit.
• Attach the red ring-type connector to the positive (+) DC terminal (red) on the power inverter and
connect the black ring type connector to the negative (-) DC terminal (black) on the Power inverter.
• Attach the negative (black) clip to the negative (-) battery terminal.
• Attach the positive (red) clip to the fuse or circuitry breaker of the 12V battery bank as indicated on
‘Typical Wiring block diagram of the Power Inverter’ on page 5.
• Unit is ready for use.
Testing the Power Inverter:
• Turn unit on by using the On/Off button on the unit. The ‘Power’ light turns on indicating the Nature
Power Inverter is ON. AC output is now available.
• Plug in a small AC load like a 25W table lamp or small appliance to the AC socket to verify AC is
available.
• The unit is successfully installed and functioning properly.
Test the GFCI monthly:
• Use the following instruction to perform a monthly test on the GFCI to ensure the GFCI is
functioning properly.
• Turn unit on and plug a small AC load (40W light bulbs) to the GFCI.
• Check the AC load is ON.
• Press ‘Test’ button and observe a click sound. Check AC load is turned off.
• Press ‘RESET’ button and check the AC load is back ON again.
WARNING:
RISK OF EQUIPMENT DAMAGE
• Do not plug surge-protected power bars into the unit’s 120 VAC outlets. The surge protected
components on the surge-protected power bar may not like the modified sine wave output
generate by the inverter.
• Do not connect an AC power source like utility power or generator to the unit 120 VAC outlets.
Turn ON and OFF the unit
• Toggle the On/Off switch to ‘ON’ position to turn unit ON.
• ‘Power’ indicator will turn green.
• 120 VAC Output is available at the AC output socket. (For 38304, 5V USB is also available.)
• Toggle the On/Off switch to ‘Off’ position to turn unit off. ‘Power’ indicator will turn off.
Problem Symptom
Solution
No AC output and
‘Power’ indicator is off.
The unit is off
Turn unit ON using the toggle switch
No power to inverter
Check fuse or the Disconnect switch (if
installed) is either blown or turn OFF
No AC output. ‘Fault’
indicator is ON
Unit detect fault and has
shutdown
Verify the error condition and make correction
and reset unit
Products connected to
unit malfunction or
overheat (38204 )
Products connected to unit do
not accept modified sine wave
output generated by the
inverter
Products are not compatible with the modified
sine wave output generated by inverter. See
“AC Load on Power Inverter” in Section 4 . Use
NATURE POWER Inverter with sine wave
output
No AC output.
‘
Power
’
indicator is ON (38304
only
)
GFCI was tripped
Check load. Reset the GFCI by pressing the
reset button on the GFCI
7. WARRANTY
Customer Service: 1-800-588-0590
Email: Info@naturepowerproducts.com
Website:
www.naturepowerproducts.com
4. UNIT OPERATION
5. TROUBLESHOOTING
To trouble shoot the unit, please note the error code display on the main unit and review the
“Understanding the Error Codes” in section 4.
Load Consumption
Estimate
Run
time
Cordless Phone
5W
150 hrs
Clock/Radio 8W
100
hrs
Table Lamp
40W/60W
27 hrs/ 18 hrs
Freezer (8.8 cu. ft.)
80W
15 hrs
20” LCD TV
100W
11.5 hrs
Sump Pump (1/2 hp)
350W
Not applicable (surge too high)
6. SPECIFICATIONS
Note: Specifications are subject to change without notices.
Specification
38304 38204
Inverter
AC Output Power
400W
AC Output Current
3.3A
3.3A
AC Surge Power (Peak)
800W
AC Output Voltage
120Vac
60Hz
120Vac
60Hz
AC Output Waveform
True Sine Wave
(<3%THD)
Modified Sine Wave
Nominal DC Input Voltage
12.5 VDC
No Load battery draw
< 0.8 ADC
< 0.3 ADC
DC Input Voltage operating range
10.5
–
15.5 VDC
Under Voltage Alarm
11.2 VDC
Under Voltage Shutdown
10.5 VDC
Under Voltage Recovery
11.8 VDC
Over Voltage Shutdown
15.5 VDC
AC Output socket
GFCI Duplex receptacle
NEMA
5-15P
DC Output
USB Output
5V / 1000mA
Not applicable
Safety and Environmental
Conformance
UL 458,
CSA C22.2 no. 107.1
UL 458,
CSA C22.2 no. 107.1
Agency Markings
cETLus
cETLus
Operating Temperature
0°C to 40°C (32°F to 104°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)
Relative Humidity
5-90% noncondensing
Operating Altitude
Up to 9,843ft (3000 meters) above sea level
Weights and Dimensions
Weights
3.8 lbs (1.73 kg)
1.6 lbs (0.73 kg)
Dimensions
6.9x7.9x2.3
”
(175x200x89mm)
4 x 6 x 2
”