A diagram for the consumed electricity, divided by hours for the
previous day.
A diagram for the active hours of the solar collector's circulation
pump, divided by hours for the previous day.
A diagram for the active hours of the boiler's circulation pump,
divided by hours for the previous day.
Note:
If the
Measured or set parameters
field is currently showing the consumed day or night
electricity, pressing and holding the
View/Enter
button for more than 1.5 seconds, resets the
parameter.
Set temperature for heating with the electrical heater*
When the water heater is on, pressing any of the buttons
▲
or
▼
activates screen for
Changing the set temperature
. Further pressing any of the same buttons changes the set
temperature in the relevant direction. The
View/Enter
button saves the new settings and the screen
goes back to its previous view. If no buttons have been pressed for 5 seconds, the display goes back
to its previous state, but the changes won't be saved. If any of the buttons
▲
or
▼
is pressed and
held for more than 0.8 seconds, the value automatically increases or decreases with 3 digits per
second.
This sets the temperature only for heating with the electrical heater!!!
The temperature limits are between 20 and 75
°С
.
The menu EL Eco Setting is more appropriate for setting the temperature, because it allows
regulating not only the temperature for turning the heater on, but also for turning it off.