Electronic pellet burner controller – NPBC-V3C-1/ NPBC-V4C-1
S
ETUP
PARAMETERS
RANGE
FOR
NPBC-V3C-1
Menu
Parameter
Unit
Min
Max
Default
Display
Brightness
level
2
10
7
Pump Settings
CH pump
Pump On
°C
35
80
60
Hysteresis
°C
2
7
5
DHW pump
WH set temp
°C
30
70
50
Hysteresis
°C
2
7
5
General Settings
Burner feeder
Operation
%
100
500
150
Extra sec
seconds
00
30
00
Max Temp
°C
35
85
85
Feeder capacity
kg/h
0.5
60.0
10.0
Flame Detection
Ignition
level
0
150
100
seconds
10
240
20
Extinction
level
0
150
40
seconds
10
240
60
Power
Modulation
P3 ΔT
°C
2
30
10
P2 ΔT
°C
1
29
05
P1 ΔT
°C
0
28
00
Duration
minutes
0
120
20
Overheating
°C
00
20
8
Cleaning
Start
Fan.
seconds
10
600
180
FC
seconds
0
250
0
Stop
Fan
seconds
10
600
180
FC
seconds
0
250
0
Alarm
Fan
seconds
10
600
180
FC
seconds
0
250
0
Cycle
minutes
10
990
120
Ignition
Ignition retries
count
0
5
3
Loading
seconds
1
120
10
Exhaust fan
speed
0
100
0
Stage 1
seconds
0
600
30
speed
--
--
--
Stage 2
seconds
10
540
120
User Manual / ver 3.8
http://www.naturela-bg.com/en/