Electronic pellet burner controller – NPBC-V3C-2 / NPBC-V4C-2
Fuel dependent settings
Press and hold the Menu button to enter the Factory Settings. Select the row Burning Setup and
press the right navigation button (►). Select the fuel type and press the right navigation button
again.
Cleaning –
This menu combines the settings for all main cleaning procedures. The fans work on
full power during these procedures. Set the duration of the cleaning cycles by setting the active time
for the main fan and the FC output for the procedures before ignition (row Start), after extinction
(row Stop) and in case of an alarm (row Alarm). The automatic cleaning is a procedure, performed
periodically during the continuous work of the burner for longer period of time. During this
cleaning the burner stops, executes the procedure for cleaning after extinction and then ignites
again. Set the time interval between two automatic cleaning procedures from the parameter Cycle
[min].
Ignition
– This menu contains all ignition parameters. If the first ignition attempt fails, the burner
can do few more. Set their number from this menu (
Ignition retries
), as well as the time for the
main auger to load the first dose of pellets for the ignition (
Loading [Sec]
). The parameter Exhaust
fan sets the exhaust fan's speed during this procedure. The ignition cycle is divided on 3 stages:
Stage 1 – only the ignition heater works
Stage 2 – the main fan works on lower speed along with the ignition heater
Stage 3 – the main fan works on higher speed along with the ignition heater
User Manual / ver3.8
http://www.naturela-bg.com/en/
стр. 32 от 37
Column for the FC output's active
time for each cleaning procedure
If the value is 0, FC output is inactive
Column for the main fan's active
Time for each cleaning procedure
Enable/Disable the automatic
Cleaning and set
The cycle between two procedures
Fuel number
Main fan's speed
Duration of the stage