Electronic pellet burner controller - NPBC-V3M
S
ETUP
PARAMETERS
RANGE
FOR
NPBC-V3M
Setup Menu
Parameter
Unit
Min
Max Default
CH Setup
Set Temp
°C
35
80
65
Hysteresis
°C
1
5
5
DHW Setup
Set Temp
°C
20
65
45
Hysteresis
°C
1
5
2
Contrast
Contrast
level
0
20
9
Cleaning on Start
Fan
seconds
10
600
180
Cleaner
seconds
0
250
2
Cleaning on Stop
Fan
seconds
10
600
180
Cleaner
seconds
0
250
2
Cleaning on BB
Fan
seconds
10
600
180
Cleaner
seconds
0
250
2
General Setup
Retries
0
5
3
Feed
seconds
1
99
10
EFan
speed level
1
100
15
Ignition Cycle Setup
Heater
seconds
0
600
30
Fan phase 1
speed level
1
100
5
minutes
1
9
2
Fan phase 2
speed level
1
100
15
minutes
1
9
3
Initial Burning
Duration
seconds
0
300
0
Fan column 1
speed level
1
100
20
Fan column 2
speed level
1
100
20
Burning Startup
1st Power Level
seconds
10
600
60
2nd Power Level
seconds
10
600
60
Burn Level
dT for 3rd Power
Level
°C
0
30
10
dT for 2nd Power
Level
°C
0
20
5
dT for 1st Power
Level
°C
0
10
0
3rd Burn Level Setup
Feed
seconds
0.1
25.0
5.0
Cycle
seconds
4
120
30
User Manual / version 2.6
http://www.naturela-bg.com/en/