Electronic pellet burner controller - NPBC-V3M
Fan column 1
speed level
1
100
100
Fan column 2
speed level
1
100
100
2nd Burn Level Setup
Feed
seconds
0.1
25.0
3.0
Cycle
seconds
4
120
30
Fan column 1
speed level
1
100
50
Fan column 2
speed level
1
100
50
1st Burn Level Setup
Feed
seconds
0.1
25.0
3.0
Cycle
seconds
4
120
20
Fan column 1
speed level
1
100
25
Fan column 2
speed level
1
100
25
Suspend Burn Level
Feed
seconds
0.1
25.0
2.0
Cycle
seconds
10
120
120
Fan column 1
speed level
1
100
5
Fan column 2
speed level
1
100
5
Burning Shutdown
3rd Power Level
seconds
10
300
60
2nd Power Level
seconds
10
300
60
1st Power Level
seconds
10
300
60
Suspend Time
Suspend Time
minutes
0
180
20
Overheating
Max
°C
0
20
0
Interm. Cleaning
Cycle
seconds
10
900
600
Duration
seconds
0
120
30
Fan, column 1
speed level
1
100
75
Fan, column 2
speed level
1
100
75
Auto Clean Setup
Cycle
hours
0
24
2
Burner Feeder
Duty
%
110
500
150
seconds
0
30
0
IR Level Setup
Detect Ignition
level
1
150
100
seconds
10
240
20
Detect Extinction
level
0
150
40
seconds
10
240
60
Set Temperature
Max
°C
25
85
85
Safety Setup
Warn
°C
150
300
200
Alarm
°C
200
350
220
Test Fan Speed
speed level
0
100
0
Test EFan Speed
speed level
0
100
0
User Manual / version 2.6
http://www.naturela-bg.com/en/
page 25 of 27