Electronic pellet burner controller - NPBC-V6T-2
The operation of the two augers, the fan and the circulation pumps is visualized with the animated
image in the middle of the main screen. When the photo sensor detect fire, a flame will appear in
the boiler. If it is necessary to display several informational messages on the bottom line at the
same time, they alternate in every 4 seconds. The date is displayed in white color, the operating
stage in green and the registered errors in red color .
If the time is not correct, the indication will be --:-- .The time must be set correctly for normal
operation of the burner.
Most of the error messages are indicated with tree-tone sound signalization.
Some of the error messages are cleared automatically after the problem is cleared. The others for
examples “Back burning”,”Boiler frost”and etc.,can be cleared after pressing and holding button
for one second.
The information fields are as follow:
Icon
Displayed information:
Temperature to which the water in the stove will heat, taking into account set
temperature and the temperature of the active timers.
Current calculated power of the burner. A calibrating constant parameter for the
auger motor's capacity must be set to assure the correct value of the burner's power.
The calibrating constant is available in the menu
Service Settings »Burning Setup
» Fuel X» "More settings"
Exhaust gas temperature
Information about the upcoming action of the timer. If there are no active timers or
the burner is in Standby mode, there is no information under the icon. If there is at
least one activated timer and the burner is ON, under the Icon there will be
information regarding the time or the day of the week of the upcoming action or if
this moment is in the interval of some of the timer, the temperature set by the timer
and how long it will be valid.
Remaining time until the end of processes with limited duration, for example
cleaning, fuelling with the initial fuel dose etc. The stages of power modulation and
maintenance are not with equal duration, because it can be interrupted by activating
a thermostat or changing the temperature, and that's why there is no information
about their ending.
Temperature measured by the temperature sensor in the water heater
Exhaust fan's speed.