Electronic pellet burner controller - NPBC-V6T-2
Fuel dependent settings
The access of this setting is through menu ''
Service settings
» Burning setup»
where you must
choose ''Fuel 1''
»''Fuel 2''» ''Fuel 3'' or ''Fuel 4''.
Cleaning –
From this menu is the setting for the duration of the cleaning cycles, with the time for
work of the main fan. If necessary the fans can be adjusted not to operate in full power. Here you
can set whether to have an automatically cleaning cycles and during what period. The Auto
cleaning cycle are as follow: extinguishing, cleaning after extinguishing and re-ignition. The
cleaning procedures are performed before ignition (row Start), after extinguishing or automatically
cleaning (row Stop) and in case of an alarm “back burning”(row Alarm). The setting for additional
fan or other cleaning mechanism are common to all fuels and can be changed from menu
''
Service settings'' » ''Additional cleaning''.
Ignition –
In this menu set the number of ignition attempts
,
the operating time of the fuel auger
for loading the first dose with pellets, the exhaust fan speed during the entire period of ignition
and maximal duration of the three stage of ignition. Also the speed of the main fan during each
stage.
If the photo sensor detects a successful ignition the procedure will be terminated and the burner
proceeds to unfolding the fire.
User Manual / ver. 1.2
http://www.naturela-bg.com/en/
page 36 of 41
Fuel number 1
Main fan speed
column
Column with duration
in seconds at each
stage fromignition
The burner will be cleaned
automatically after
120 minutes
continuous combustion