Page
27
of
31
Re-seal caulk on all jambs. Coat entire threaded portion of all bolts for
doors and covers with a never-seize product.
5. Plumbing:
Ensure fittings are tight at all locations.
6. Water Jacket:
Over-fill
so float pointer is 4” above rubber cap
, re-seal caulk.
7. Pump:
Remove bleeder screw and flush, inspect and turn shaft with screwdriver.
See
maintenance section for further details.
8. Water Treatment:
Make sure water is tested and ha
s enough Nature’s Comfort water
treatment. See warranty for further details.
9. Misc:
Sand and paint any rust.
Moisture from condensation or rain must not be allowed to accumulate in the firebox or ash
pan during the off-season. Failure to perform preventive maintenance may result in severe
corrosion and major damage to the boiler.
This is not covered under warranty.
Going Away
When going away during freezing weather and no one will be keeping the boiler going, turn the rear
control switch off and keep the circulation pump running and turn the backup heat system on. The
boiler will now operate in reverse heat being kept above freezing by the backup system eliminating
the need to otherwise drain the boiler, invest in anti-freeze or find someone to load wood.
Please keep this manual with all other important papers. The information in this manual is
necessary for the installation, operation and proper use of the boiler. If you should ever have a
problem or question refer to this manual or call your dealer. If your dealer does not have the
information you need, request they contact Nature’s Comfort and your dealer will be further
educated to provide the best possible customer service. Please keep in mind
that Nature’s Comfort
built the boiler but did not install it and has no control over the installation, operation, efficiency of
the building’s insulation or what is burned in the boiler.
Disclaimer
All installation and operation must follow Federal, Provincial, State and Local codes, ordinances
and laws.
Nature’s Comfort boilers are not intended to be used in urban areas.
Nature’s Comfort boilers are not intended to be the only source of heat. A backup system should
always be in place and ready for use.
Nature’s Comfort boilers are
not intended to and must not operate under pressure.
All electrical and plumbing should be done by qualified personnel and conform to national, state and
local electrical, plumbing, fire and building codes.
Manufacturer is not liable for damages to personnel or property for misuse, improper installation of
equipment or for knowing Federal, Provincial, State and Local codes, ordinances and laws including
local installation codes. Owner assumes all responsibility for this.
See warranty for further details.