background image

 

https://www.naturewater.eu 

 

Item 64404

 

Page 3 

 

 

  

 

01 2024-1

 

 

Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Safety instructions

 

 

 

Regularly clean and replace the filter cartridges.

 

 

Do not disassemble the parts randomly; this could provoke leakages or damages.

 

 

Do not use mains adaptors the voltage of which is not suitable.

 

 

Before storing the device for a long period, disconnect the mains plug and close the water 
tap.

 

 

Do not store or use the device when the ambient temperature is 0

 

 or below.

 

 

Proceed with caution when installing or unmounting a cartridge or when moving the device.

 

 
 

Other instructions

 

 

 

When not using the device, interrupt the water supply and close the ball valve to avoid damages 
caused by water hammers. Uncontrolled water hammers might cause leakage or damages to 
the filter housing. Warranty is excluded for damages caused by water hammers.

 

 

When problems occur, disconnect the device from the mains and water supply and contact an 
expert. Changing the filter might repair the problem.

 

 

The device vibrates during operation.

 

 

It is recommended to have an expert replace the cartridge.

 

 

With insufficient water supply, the control lamp is yellow, a buzzer sounds during 5 s.

 

 

After 50 hours of operation, the indicator is green, and the buzzer sounds during 10 s. At the 
same time, the system shuts down and reminds the user of replacing the 3 pre-filters. The cal-
culation of the service life of the filters is reinitialised after new start.

 

 

Note!

 

 

When operating the device for the first time, check the system for correct installation and smooth 
operation before opening the water tap. Rinse the filter during 10–15

 

min before using the water 

for alimentation purposes.

 

 

Wait for the system to normally run during more than 90

 

min before performing any test.

 

 

 

Summary of Contents for 64404

Page 1: ...rating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further...

Page 2: ...ave found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent v...

Page 3: ...ly and close the ball valve to avoid damages caused by water hammers Uncontrolled water hammers might cause leakage or damages to the filter housing Warranty is excluded for damages caused by water ha...

Page 4: ...ed carbon filter COC 2 reverse osmosis membrane RO and activated carbon post filter T 33 3 Accessories box including water faucet three way valve three hoses user s manual adaptor and drain clamp Draw...

Page 5: ...Name description 1 Reverse osmosis water faucet 6 Water drain hose red tube 2 Feed water tap 7 Reverse osmosis water hose blue 3 Energy 8 Water inlet hose white tube 4 Reserve at least 100 mm for pip...

Page 6: ...plates gaskets and nuts in the order shown and tighten them on the worktop Fix the reverse osmosis water line blue to the un derside of the water faucet then connect the line to the device Attention M...

Page 7: ...tops producing pure water the indicator lamp lights up red The buzzer sounds 30 times after 6 hours of uninterrupted operation or if a water leak has been detected Replacing the cartridges and maintai...

Page 8: ...turn off the water close the tap open the reverse osmosis tap and drain the water in the pipe 2 Tilt the cartridge by 30 turn it anti clockwise and remove it 3 Insert the new cartridge by turning it c...

Page 9: ...m 250 Chlorine content of feed water ppm 0 2 Rejection 90 99 Feed water pressure bar 1 4 Stability against electric shocks Type 2 Process chart of water treatment Name Name 1 Feed water 7 Reverse osmo...

Page 10: ...switch damaged Exchange high pressure switch Pump blocked adapter fuse blown Replace adapter repair water pump Water pump is running but system is not working Reverse osmosis membrane ob structed Repl...

Page 11: ...other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic...