RC40 Control manual
59
is abnormal;Whether the file
is too large, or the disk does
not have enough space
e0x0039
An error occured
while backing up
file
An error occurred while
backing up the file
The file does not exist
e0x003A
An error occured
while restoring file
Failed to restore the file from
the backup file path
The file does not exist
e0x0050
Robot program
error
There are errors in the
instructions used in the
program, such as input
parameter error, the absence
of points, or variable types
that do not match the desired
type
Check whether the
parameters and variables
used in the instruction are
valid according to the alarm
line number and prompt
message.
e0x0051
An error occurred
while updating the
system
The controller hardware
exception caused a system
update error
Contact technical support
e0x0052 Point file error
The point file in the controller
is in the wrong format
Create a new project or
replace the abnormal point
file with a normal point file,
then re-teach the point and
download it to the controller
e0x0053
User coordinate file
error
The user coordinate file in the
controller is in the wrong
format
Create a new project or
replace the abnormal user
coordinate file with a normal
user coordinate file, then re-
calibrate the user