RC40 Control manual
70
Adjust the drive to improve
position tracking (accuracy),
or increase PEMAX to
tolerate large position
errors;
e0x1008 Phase Find Failed
Communication initialization
fails. The fault occurs when
the system does not receive
commutation information of
the motor feedback device
(for example, Hall signal). The
fault will disable the driver.
Check the motor type and
phase parameters are
correct
e0x1009 Drive Locked
The security code does not
match the key. The drive
cannot be operated
Contact technical support
e0x1011 STO Fault
When the STO signal is not
connected when the drive is
disabled, the failure will
disable the drive.
Check the STO connector
of the driver is connected
correctly;
e0x1012 Over-Voltage
The bus voltage exceeds the
maximum value. This fault will
disable the driver.
Check whether the
equipment needs
regenerated resistance
e0x1013
Motor Over-
Temperature
Motor overheating, or the
driver's temperature sensor is
not set correctly, this fault will
disable the driver;
Contact technical support
e0x1014
Power Module
Over-Temperature
The temperature on the
integrated power module
Check whether the ambient
temperature exceeds the
drive specification,