RC40 Control manual
92
4.Repair or replacement
drive;
e0xFF2C
Encoder external
communication
transmit abnormal
1.The encoder connection
error;
2.The encoder cable damage;
3.The encoder is damaged;
4.The encoder parameter
setting er
1.Check the encoder
connection;
2.Check the encoder
cables;
3.Replace the encoder;
4.Check the encoder
parameters
e0xFF2F
Encoder external
communication
receive abnormal
1.The encoder connection
error;
2.The encoder cable damage;
3.The encoder is damaged;
4.The encoder parameter
setting error;
1.Check the encoder
connection;
2.Check the encoder
cables;
3.Replace the encoder;
4.Check the encoder
parameters
e0x2320
Drive hardware
overcurrent
Motor load is too large, or
control parameters setting is
not correct, motor fault;
Check the motor load, or
increase the motor capacity,
check the motor parameters
and control parameters
setting, repair or
replacement motor;
e0x3130
Input lack-phase
fault
1.The input power supply
lacks;
2.0 x202c parameter
selection three-phase input
power source, the actual
access to the single phase
input power source;
1.Check the power supply
circuit, main circuit
connected in a state of a
certain phase voltage is too
low or use the single-phase
power supply;
2.According to the actual
access power set parameter