background image

User Manual - Stand-Up Lift: BLUE WAYUP PLUS with electrical opening legs

Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)

21

Motorisation Technicals Characteristics

A. LCM DISPLAY

0. Information display

- To view the information registered 

in the control box, you must press the 

up and down buttons of the box for 5 

seconds.

1. Operating factor

- Definition: It accounts for the actua-

tor (up / down) any breach of the duty 

cycle = non-respect of the actuator rest.

2. Overloading of the actuator / a

- It counts the number of times an 

attempt to lift a person weighing 

beyond the maximum weight limit is 

performed. When it occurs, the actua-

tor will stop and an anvil will appear, it 

will be impossible to continue.

3. Overloading of the actuator / b

- It counts the number of times an 

attempt to spread or close the opening 

legs while they are stuck is performed. 

When it occurs, the actuator will stop 

and an anvil will appear, it will be 

impossible to continue.
4. Incomplete load

- It records all incomplete loads below 

24,6V. This corresponds to the number 

of charges damaging the battery.

5. Time of use

- Definition: It displays the cumulative 

operating time of the device. Starting 

from 600,000 seconds of use, a mainte-

nance key is displayed; it is then essen-

tial to carry out a complete control of 

the device.

Summary of Contents for BLUE WAYUP PLUS

Page 1: ...ISO 10535 2007 STAND UP LIFT BLUE WAYUP PLUS with electrical opening legs User Manual Stand Up Lift BLUE WAYUP PLUS with electrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghiz...

Page 2: ...Use Stand up Lifts Use Motorisation Informations Users Guide Slings Use Reuse Labelling Preventive Maintenance Security Controls General Safety Guidelines Technicals Dimensionals Characteristics Spar...

Page 3: ...air It is permitted to be used in wet areas For example this includes the toilet or the bath This does not include using the patient hoist under the shower The stand up lift BLUE WAYUP PLUS with elect...

Page 4: ...the base Put the nuts covers 1 2 Assembling Instructions BEFORE USING YOUR STAND UP LIFT IT IS NECESSARY TO CHECK The wheels turn and roll normally The rear wheels function correctly There is no wear...

Page 5: ...hand wheel on the side Your stand up lift Is ready for use Assembling Instructions User Manual Stand Up Lift BLUE WAYUP PLUS with electrical opening legs Manufactured by NAUSICAA M dical S A S Approv...

Page 6: ...bating against osteoporosis and all disorders associated with immo bility such as falls during transfers stimulate brain activity thus favouring maintenance of continence improves intestinal activity...

Page 7: ...at can be raised by the stand up lift Do not force the controls and features of the stand up lift they are all easy to use and do not require strength Operate the stand up lift by pushing the handles...

Page 8: ...se the castors press the parking lever pointing upwards Castor Released When locking the castors always insure that both castors are locked If only one castor is locked on a sloping floor the unlocked...

Page 9: ...roved by Ghizlane Labrosse Biomedical Engineer Before use check that the actuator and the hand control are correctly connected to the control unit page 22 Check the status of the control box and the b...

Page 10: ...with electrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer Down Closing Opening Down Overload Maintenance Battery level indication Up Up Clos...

Page 11: ...ach sling In order to choose the right sling the caregiver shall take into account the patient s waist size All our slings provide sustainable solutions for reassuring transfers and are compatible wit...

Page 12: ...plastron Hook the two fasteners of the backrest to the stand up lift hooks SETTINGS The fastening system with multiple hangers allows to adjust the position of the person Operate the actuator until h...

Page 13: ...pproved by Ghizlane Labrosse Biomedical Engineer Labelling on the box Reuse The stand up lift is suitable for repeated use The stand up lift must be cleaned disinfected and serviced according to the P...

Page 14: ...ORL Y MAINTAINED BATTERY DETERIORATES SAFETY INSTRUCTIONS BEFORE EACH USE Verify the presence and conditions of safety devices all axis and their constrained fixations pins clips and bolts and the tig...

Page 15: ...Labelling 1 5 4 3 2 User Manual Stand Up Lift BLUE WAYUP PLUS with electrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 13...

Page 16: ...l S A S Approved by Ghizlane Labrosse Biomedical Engineer A Operation of the actuator B Operation of the emergency system C Batteries status charge holding D Handcontrol status E Control operation on...

Page 17: ...lectrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 1 Connection head of the actuator bolted 2 Connection base of the actuator bolted 3 Conn...

Page 18: ...adequate measures and instructions that mechanical stress of the charging cord through bending tension shear crushing is excluded during loading or cleaning of the part This also applies to the electr...

Page 19: ...d the SCP at its Maximal Height 880 l Minimal Distance Between the Wall and the SCP at its Maximal Height 360 m Maximal Diameter 1140 SCP Suspension central point Frame made in steel Laser cutting and...

Page 20: ...EMB 8000N LIFTING ACTUATOR BASE SCREED all models 15 00 146 VS VRN 8 CAR 8000N all models AND 3000N VSNLV VRN LIFTING ACTUATORS COMPLETE CASING 15 00 147 VS VRN 6 8 CRD 6000N AND 8000N LIFTING ACTUATO...

Page 21: ...cility Biological cleaning operation Steam cleaning of various flat surfaces Change surfaces regularly when washing to avoid water load Steam cleaning of inaccessible areas For tubes steam use with a...

Page 22: ...Protection class II Protections types Remote control IP54 Control box IP65 Battery pack IP65 Actuator IP55 Stop limit switch Box in ABS Handcontrol with spiral cable low voltage 24V Protection agains...

Page 23: ...mpt to lift a person weighing beyond the maximum weight limit is performed When it occurs the actua tor will stop and an anvil will appear it will be impossible to continue 3 Overloading of the actuat...

Page 24: ...e battery and the control box 3 Batteries are unloaded 4 The remote control jack is not plugged 5 The remote control jack is deteriorated 6 There are damages on the remote control or on the control bo...

Page 25: ...ection alteration or transformation not validated by NAUSICAA M dical S A S the impact of external elements natural disaster fire shock humidity flood lightning installation and or use in a non compli...

Page 26: ...User Manual Stand Up Lift BLUE WAYUP PLUS with electrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 24...

Page 27: ...User Manual Stand Up Lift BLUE WAYUP PLUS with electrical opening legs Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 25...

Page 28: ...66 717 184 Fax 33 0 466 532 305 Email export nausicaa medical com Website www nausicaa medical eu Manufactured by NAUSICAA M dical S A S 12 All e du Piot ZA P le Actif 30660 Gallargues le Montueux FRA...