All Stages of Tuning Procedure
Page 2-20
ATU-HP Technical Instruction Manual
Issue 2.0
Section 2 Preparation for Use and Installation
DGPS Applications
Table 2-6a:
Loading Coil (DGPS) Series Connection (500-136
μ
H)
Inductance
(
μ
H)
L1A
input
L1A
output
L1B
input
L1B
output
480 1
13 1 12
460 1
13 1 11
440 1
13 1 10
390 1
11 1 10
350 1
10 1 9
320 1
11 2 9
275 2
11 2 9
250 2
10 2 9
235 2
10 2 8
215
2
9
2
8
195 2 9 2 7
180 3 8 2 8
164 3 8 2 7
145 3 8 2 6
Figure 2-12a: Loading Coil (DGPS) Series Connection (500-136
μ
H)
(215
μ
H shown)