All Stages of Tuning Procedure
Page 2-24
ATU-HP Technical Instruction Manual
Issue 2.0
Section 2 Preparation for Use and Installation
High Power NDB Applications
Table 2-6e:
Loading Coil (NDB High Power) Series Connection (1200-300
μ
H)
Inductance
(
μ
H)
L1A
input
L1A
output
L1B
input
L1B
output
1150
1 14 1 14
1050
1 13 1 13
950
1 12 1 12
840
1 11 1 11
730
2 11 1 10
680
2 10 1 10
630
2 10 1
9
580
3
10
2
10
530
3 10 2
9
480
3 9 2 9
450
4 10 3
9
400
4 9 3 9
350
4 9 4 9
310
4 8 4 9
Figure 2-12e: Loading Coil (NDB High Power) Series Connection (1200-300
μ
H)
(580
μ
H shown)