GV60 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.8
VERSION 1.0 2018-01-01
View Alarms Screen
If an alarm exists and is currently being recognized by the transmitter system, it is displayed in the
View
Alarms
screen (
Main Menu -> View Status -> View Alarms
) of the controller UI display (see
).
Figure 4.1.3: View Alarms Screen
1.
Scroll through the
View Alarms
screen to view the active faults.
2.
Attempt to clear any latching alarms by pressing the checkmark button in the
Main Menu ->
Reset Alarms
screen. If the alarm persists, it will not clear from the display.
3.
Locate the alarm name in
to determine the cause of the alarm and
perform any recommended procedures in the
Description and Troubleshooting Action
column.
This may also lead to replacing a suspect PWB, power supply or fan, as detailed in
NOTE
: Before undertaking any troubleshooting, record all meter readings and note if any other alarms
are displayed on the
View Alarms
page
.
Record all alarms.
NOTE
:
Alarms
that can occur, sorted
alphanumerically for each sub-system, including both the names displayed on the AUI and, if different,
the controller UI (in parentheses). The
Description and Troubleshooting Action
column provides a
brief description of the alarm, troubleshooting tips and a cross-reference to more detailed
troubleshooting, as applicable.
4.
If troubleshooting and subsequent replacement of a suspect PWB or module causes the alarm to
disappear from the
View Alarms
screen, the alarm has been successfully cleared. If the fault
condition does not clear, contact Nautel.
Summary of Contents for GV60
Page 2: ......
Page 4: ......
Page 8: ...GV60 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 1 0 2018 01 01 ...
Page 102: ...GV60 TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 12 VERSION 1 0 2018 01 01 ...
Page 463: ...VERSION 1 0 2018 01 01 MD 17 Figure MD 17 NAPA31C Power Amplifier PWB Q1 ...
Page 475: ...GV60 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 1 0 2018 01 01 ...
Page 476: ......