GV60 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.52
VERSION 1.0 2018-01-01
1.
Use the transmitter’s AUI (local or remote) or controller UI alarm status/logs to isolate the defective
low voltage power supply (LVPS), noting there may be redundant (dual) supplies installed, or
Power Supply module.
2.
Open the transmitter front door and locate the suspect LVPS / Power Supply module. See
for cabinet A and
3.
or
Power Supply module from the front of the transmitter.
4.
Locate or obtain a replacement LVPS / Power Supply module (Nautel Part # UG92*).
5.
or
LVPS / Power Supply module.
Figure 4.1.17: Removing/Installing LVPS / Power Supply Modules
AC OK
and
DC OK
LEDs should be on (green)
after successful power supply installation.
If the associated RF power module is disabled,
the
DC OK
LED will not turn on until the module
is enabled.