NV5LT/NV3.5LT TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.18
VERSION 3.3 2016-03-10
Controller: +5V A Fail Power Supply (red)
This alarm occurs if the +5 V supply in the controller is 10% lower or 10%
higher than the desired value. Check the output voltage of the LVPS module.
If necessary, replace the LVPS (see
). There may also be a problem with the
controller’s power supply PWB.
Controller: +5V B Fail Power Supply (red)
This alarm occurs if the sec5 V supply in the controller is 10%
lower or 10% higher than the desired value. Check the output voltage of
the LVPS module. If necessary, replace the LVPS (see
Supply Module Replacement” on page 4.1.46
.
There may also be a
problem with the controller’s power supply PWB.
Exciter A/B: AES
Digital 1 Audio Low
(Dig 1 Aud Low)
Exciter (amber)
This alarm indicates the Digital 1 input level is too low or is not applied. The
threshold and timing for this alarm can be adjusted in the Audio Low menu
in the user interface (see
“Setting Low Audio Thresholds” on
) of the Operations & Maintenance Manual.
Exciter A/B: AES
Digital 2 Audio Low
(Dig 2 Aud Low)
Exciter (amber)
This alarm indicates the Digital 2 input level is too low or is not applied. The
threshold and timing for this alarm can be adjusted in the Audio Low menu
in the user interface (see
“Setting Low Audio Thresholds” on
) of the Operations & Maintenance Manual.
Exciter A/B: Analog
Left (or Right) Audio
Low (Anlg L or R Aud
Low)
Exciter (amber)
This alarm indicates the analog left or right audio input level is too low or is
not applied. The threshold and timing for this alarm can be adjusted in the
Audio Low menu in the user interface (see
) of the Operations & Maintenance
Manual.
Exciter A/B: Audio
Processor Offline
(Audio Proc Offline)
Exciter (amber)
This alarm occurs if the exciter is configured to include an Orban Inside
audio processor, but it is not communicating with the processor on the
internal serial bus. Check all connections to the Orban Inside audio
processor card.
Exciter A/B: Audio
Processor Output Fail
(Audio Proc O/P Fail)
Exciter (amber)
This alarm occurs if the exciter is configured to include an Orban Inside
audio processor, but it is not detecting audio from the processor. Check all
connections to the Orban Inside audio processor card.
Exciter A/B: Audio
Shutdown
Exciter (red)
This alarm occurs if the exciter’s audio processing and FM modulation code
is shut down. Should display only during a software upgrade.
Exciter A/B: DSP
Audio Reset
Exciter (red)
This alarm indicates that the exciter has detected a misalignment in the
audio buffers and has restarted the audio processing in the DSP. If the
condition persists or re-occurs, this may indicate a fault with the exciter
hardware.
Device and
Alarm Name
(AUI, UI)
Front Panel LED
(color)
Description and Troubleshooting Action
Summary of Contents for NV3.5LT
Page 2: ......
Page 4: ......
Page 8: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 3 2016 03 10 ...
Page 294: ...VERSION 3 3 2016 03 10 SD 32 Figure SD 32 NAFP109B Output Power Probe and Sample PWBs ...
Page 307: ...VERSION 3 3 2016 03 10 MD 8 Figure MD 8 NAPA31C Power Amplifier PWB Q1 ...
Page 322: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 3 2016 03 10 ...
Page 323: ......