Power Supply Interface PWB Replacement
Using
as a guide, replace the power supply interface PWB (A1) as follows:
Figure 4.1.27: Power Supply Interface PWB Location
1.
Turn off and lock out the transmitter’s main ac power.
2.
Remove the transmitter’s lower, rear panel and front panel.
3.
From the front of the transmitter, pull the power supply modules that are mated with the power
supply interface PWB forward so that they disengage from the PWB.
4.
From the rear of the transmitter, disconnect the mating connectors and wiring from the power
supply interface PWB. Record the placement of all wiring and jumpers to ensure the replacement
PWB connections are identical.
5.
Remove 24 sets of M3 nuts and washers that secure the power supply interface PWB to the
transmitter and pull out the power supply interface PWB.
M3 securing hardware
(24 nuts/washers)
Power Supply
Interface PWB (A1)
PARTIAL REAR VIEW