NX200 Main-Standby Transmitter System Instruction Manual
Page
2-85
Section 2 Preparation for Use and Installation
Issue 0.3
(j) Verify transmitter B is operating alarm free into the test load at the minimum power preset.
(k) Select the assigned power level on transmitter B and verify it is operating at the correct
power level.
(l) Open an external interlock or remove the jumper from the
SYSTEM INTERLOCK
terminals
(TB2-3 and TB2-4) on the control/monitor assembly. The forward power reading shall
immediately fall to 0 W.
(m) Close the external interlock or restore the jumper. The forward power reading shall be
restored. Testing is complete.
(n) Set the control/monitor assembly's
TRANSMITTER TO ANTENNA
toggle switch for the
desired configuration (transmitter A or B to antenna) and set the transmitters for the
desired power level. The system is not configured for automatic changeover operation.