NX50 Troubleshooting Manual
Responding to alarms
Page 1-64
Issue 6.0 2019-04-01
Control/interface PWB replacement
1. Record the following information (as a minimum) from the front panel AUI:
– Presets
page: record settings for all desired presets
–
Scheduler
page: record
Rules
and
Daily Events
information
–
Factory Settings
page: record information in the
RF Symmetry, Transmitter
Frequency, PDM Settings
and
Transmitter Type
menus
–
System Settings
page: record all information in the
Exciter Clock Calibration, RF
Monitor Level
and
Power Lockout
menus
–
User Settings
page: record all information in the
Network Setup
menu
–
Remote I/O
page: record all information for the user-defined remote
Inputs
and
Outputs
, including
Channel
and
Control
settings
–
Changeover
page: record all information
2. Set the transmitter to its
RF Off
state. Turn off (disable) the ac power at the source.
Open the front door to gain access to the exciter panel (see
3. Disconnect all cables attached to the control/interface PWB (A11A1), taking note of
the connector labels on the cables and the PWB.
4. Remove and retain the two screws securing the connector bracket in the upper, right
portion of the control/interface PWB.
5. Remove either the remote interface PWB (A11A4) (see
) or both digital AM exciter PWBs (A11A2 and A11A3) (see
“Digital AM exciter PWB replacement” on page 1-66
), whichever is easier. It may be
helpful to gently pry the connectors loose with a screwdriver
keeping to the far left or
right edge of the connector, alternating between connectors to avoid damage.
6. Remove and retain 13 sets of mounting hardware from the control/interface PWB
(A11A1).
7. Obtain a replacement control/interface PWB (Nautel Part # NAPC160B/01).
8. Set the
EXT CONT INTLK
(E1) and
REMOTE SUPPLY
(E3) jumpers on the replacement
PWB to the same positions as the defective PWB.
9. Install the new control/interface PWB by reversing
connector mating assistance, refer to the connector mating tables in
“Wiring/connector lists” on page 3-1
.Enable (switch on) the ac power for the
transmitter.
10. Upgrade the subsystem software using the AUI’s
Upgrade Software
page under the
System Settings
menu by running an upgrade using the existing .tgz file already
Summary of Contents for NX50
Page 2: ......
Page 4: ......
Page 8: ...NX50 Troubleshooting Manual Page viii Issue 6 0 2019 04 01...
Page 10: ...NX50 Troubleshooting Manual Page x Issue 6 0 2019 04 01...
Page 108: ...NX50 Troubleshooting Manual Responding to alarms Page 1 98 Issue 6 0 2019 04 01...
Page 153: ...NX50 Troubleshooting Manual Reading Electrical Schematics Page 4 6 Issue 6 0 2019 04 01...
Page 184: ...Issue 6 0 2019 04 01 MD 4 Figure MD 4 NAPI95A 01 Power Module Interface PWB...
Page 188: ...Issue 6 0 2019 04 01 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Page 192: ...Issue 6 0 2019 04 01 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Page 198: ...Issue 6 0 2019 04 01 MD 18 Figure MD 18 Fan Tray Assembly 207 8133 B1 B2 J1 AIR FLOW AIR FLOW...
Page 201: ...Issue 6 0 2019 04 01 MD 21 Figure MD 21 NAFP106B 01 Directional Coupler A1 DETAIL...
Page 204: ......