VS1 Troubleshooting Manual
Responding to alarms
Page 1-28
Issue 10.0 2018-10-29
Troubleshooting tips
AUI lockup
If the remotely accessed AUI screen stops responding, and subsequent attempts to re-access the AUI
are unsuccessful, verify that all network settings are correct (see
Network Setup
in the Operations
and Maintenance Manual). If all network settings are correct and the AUI continues to be
inaccessible, perform the
ARM Reset
procedure in the Operations and Maintenance Manual. If the
AUI is still inaccessible, try cycling (turn off, then on) the ac power. If the problem persists, contact
Nautel for further assistance.