XR12 Installation Manual
Commissioning tasks
Page 11-6
Issue 3.0 2009-07-15
Going on-air
Important:
Before going on the air, if you want the safety interlocks to operate properly, the shorting
jumpers installed in
“Turning on the transmitter” on page 11-3
,
should be removed.
When the commissioning tests are successfully completed, connect the studio audio to the
transmitter's audio input terminals, connect the RF output to its antenna system, and complete any
emission tests that are required.
1. Turn off the power using the ac disconnect switch, if one is being used, or else at the ac
source.
2. Connect the transmitter's RF output to an antenna system (or verify that the current
connection is intact).
3. Turn the transmitter’s ac power back on.
4. Use the transmitter controls and graphic user interface to begin transmitter operations. For
detailed instructions, refer to the
XR12 Operating and Maintenance Guide.
WARNING:
If a jumper is placed between interlock inputs TB1-1/TB1-2 on the
remote interface pwb, safety features controlled by the external
interlocks will be disabled. A fail safe method of alerting personnel to
this fact should be implemented. Voltages which are dangerous to life
will be present on the RF output stages and the antenna system if the
transmitter is turned on.
Summary of Contents for XR12
Page 2: ......
Page 4: ......
Page 16: ...XR12 Installation Manual Page xvi Issue 3 0 2009 07 15...
Page 22: ...XR12 Installation Manual Unpacking and positioning Page 2 4 Issue 3 0 2009 07 15...
Page 26: ...XR12 Installation Manual Installing the power transformer Page 3 4 Issue 3 0 2009 07 15...
Page 36: ...XR12 Installation Manual Installing the RF connector Page 6 6 Issue 3 0 2009 07 15...
Page 48: ...XR12 Installation Manual Adjusting the spark gap Page 7 12 Issue 3 0 2009 07 15...
Page 78: ...XR12 Installation Manual Parts and tools Page 12 4 Issue 3 0 2009 07 15...
Page 91: ......