13

OPTIONAL ACCESSORY

Vacuum valve system

remove the plug of M16 accessory 

port from the housing

remove the cap from the vacuum 

valve

slightly lubricate the o-ring and 

tighten the vacuum valve to the 

housing with the tool provided

connect hand pump to the valve 

and pump several times until it 

reaches the target vacuum level 

close vacuum valve cap

It is recommended to leave the housing 

for at least 20mins to ensure it is sealed. 

If the LED light changes from steady 

green light to rapidly flashing yellow 

light, that means there is a leakage and 

please check every O-ring and conduct  a 

vacuum test again.

hand pump

accessory port

on housing

vacuum valve

1

2

Moisture alarm window colour indication :

Steady Blue

Flashing Blue

Steady Green

Steady Red

Flashing Yellow

Flashing Red

Alternating 

Blue and Red

device is turned on
standby mode,

ready for pumpng

target vacuum level

is reached

out of battery

vacuum level

is dropping

vacuum is totally lost,

circuit stalled untill 

device is switched off

vacuum is totally lost,

circuit stalled untill 

device is switched off

* drawings as illustrations only

Summary of Contents for NA-R50

Page 1: ...Manual Housing APS C COMPACT PN 17340 17340P Introduction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Housing Mount Opening the housing 9 Closing the housing 10 13 Pre...

Page 2: ...we suggest that you reuse all pack aging materials for future travelling Allen key set Spare Silicone Rubber O ring 90131 O ring Remover Manual Instruction Card Padded Travel Case NA R50 intergrated f...

Page 3: ...ey are supervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead t...

Page 4: ...lock Magnify button AF point index reduce button Up exposure compensation button Down erase button Playback button Info button Right self timer drive mode button Menu button Left AF MF button 1 2 3 4...

Page 5: ...t dial ISO button Optical fiber cable connection M10 threaded hole Bayonet mount II release button M16 Accessory port Main switch Moisture alarm window Mode dial 1 5 9 2 6 3 7 4 8 5 PART NAMES AND FUN...

Page 6: ...6 PART NAMES AND FUNCTIONS Back Side Views Zoom Focus knob Sacrificial zinc anodes Housing unlock button Flash On Off switch 5 1 4 Threaded tripod holes 1 3 2 4 5 4 3 2 1...

Page 7: ...Adjustable right handle II Flexitray plate II W with left handle Hand strap for Mirrorless IL camera compact camera housing Standard Long hand strap for Mirrorless IL camera compact camera housing St...

Page 8: ...THE HOUSING 2 3 1 depress housing unlock button turn housing lock latch anti clockwise to open the housing flip open the back housing when lock latch is aligned to open position drawings as illustrat...

Page 9: ...thing is caught between front and back housing and that they are fully aligned before locking main O ring insert the housing shaft into the shaft hole and then rotate the lock latch clockwise until yo...

Page 10: ...y Screen Installing the Camera 2 1 3 4 Lift up the camera flash Press down the ON LOCK OFF lever and make sure it is aligned with camera control lift up the ON LOCK OFF lever each time before installi...

Page 11: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Page 12: ...es with a dampened cotton bud the alarm will give a repeating beep and the moisture alarm window will flash RED press the battery down until it click into place please contact our authorized service c...

Page 13: ...t changes from steady green light to rapidly flashing yellow light that means there is a leakage and please check every O ring and conduct a vacuum test again hand pump accessory port on housing vacuu...

Page 14: ...ot travel with camera inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommend cleaning and inspecting the main O ring each time after diving for any...

Page 15: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Page 16: ...d shoe 25131 LCD Magnifier attachment rails for NA RX100III RX100IV RX100V RX100VI 71208 Adjustable right handle II for Easitray II Flexitray II 25321 Long strobe mounting ball for cold shoe HDMI CONN...

Page 17: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Reviews: